A-16 M370185-01
S
C
PI
C
o
mm
an
d
R
e
fe
re
n
ce
Trigger
*TRG
Trigger system
N/A
Self-Test
Query
*TST?
[:]SYSTem[<channel>]:TEST?
Perform unit Self Test
(Pass=0).
Yes
Wait To
Continue
*WAI
[:]SYSTem[<channel>]:WAIT
Wait to continue command.
N/A
Table A-2
Readback Commands
Function
SCPI Command
Description
Parameter and
Range
Query
Read Output
Current
[:]MEASure[<channel>][:SCALar]:CURRent
[:DC]?
Measure and readback
output current at the
output terminals.
Yes
Read Output
Voltage
[:]MEASure[<channel>][:SCALar][:VOLTage]
[:DC]?
Measure and readback
output voltage at the
output terminals.
Yes
Read APG
Input Voltage
[:]MEASurement
[:SCALar]:APRogram
[:VOLTage][:DC]?
Measure and readback the
voltage being input to the
non isolated voltage analog
programming input pin.
Yes
Read Isolated
APG Input
Voltage
[:]MEASurement
[:SCALar]:APRogram
[:VOLTage]:ISOLated
[:DC]?
Measure and readback the
voltage being input to the
isolated voltage analog
programming input pin.
Yes
Read APG
Inpu
t Voltage
[:]MEASurement
[:SCALar]:APRogram
:CURRent[:DC]?
Measure and readback the
voltage being input to the
non isolated current analog
programming input pin.
Yes
Read APG
Input Voltage
[:]MEASurement
[:SCALar]:APRogram
:CURRent:ISOLated
[:DC]?
Measure and readback the
voltage being input to the
isolated current analog
programming input pin.
Yes
Table A-1
IEEE 488.2 Commands (Continued)
Summary of Contents for Soresen XTR 100-8.5
Page 2: ......
Page 16: ...xiv ...
Page 28: ...1 8 ...
Page 50: ...Local Operation 3 8 M370185 01 Figure 3 3 Front Panel Menu System ...
Page 93: ...Using Multiple Power Supplies M370185 01 3 51 3 ...
Page 94: ...Local Operation 3 52 M370185 01 ...
Page 128: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370185 01 ...
Page 198: ...Remote Operation 5 70 M370185 01 ...
Page 261: ...SCPI Command Tree M370185 01 A 35 A ...
Page 262: ...A 36 ...
Page 279: ...Index M370185 01 IX 3 described 3 7 3 36 number available 3 36 stored values 3 36 ...
Page 280: ...IX 4 ...