A-20 M370185-01
S
C
PI
C
o
mm
an
d
R
e
fe
re
n
ce
Calibrate the
Voltage
controlled
Non Isolated
Current APG
feature
[:]CALibration[<channel>]:OUTPut
:ANALog:CURRent
Calibrate the current analog
programming system.
? | <NR1> |
<nothing for
interactive mode>
Yes
Calibrate the
Voltage
controlled
Isolated
Current APG
feature
[:]CALibration[<channel>]:OUTPut
:ANALog:CURRent:ISOLated
Calibrates the current
analog programming
system.
? | <NR1> |
<nothing for
interactive mode>
Yes
Calibrate the
Resistive
controlled
Non Isolated
Voltage APG
feature
[:]CALibration[<channel>]:OUTPut
:ANALog[:VOLTage]:RESistive
Calibrate the Resistive
controlled voltage analog
programming system.
? | <NR1> |
<nothing for
interactive mode>
Yes
Calibrate the
Resistive
controlled
Isolated
Voltage APG
feature
[:]CALibration[<channel>]:OUTPut
:ANALog[:VOLTage] :RESistive:ISOLated
Calibrates the Resistive
controlled voltage analog
programming system.
? | <NR1> |
<nothing for
interactive mode>
Yes
Calibrate the
Resistive
controlled
Non Isolated
Current APG
feature
[:]CALibration[<channel>]:OUTPut
:ANALog:CURRent:RESistive
Calibrate the Resistive
controlled current analog
programming system.
? | <NR1> |
<nothing for
interactive mode>
Yes
Table A-4
SCPI Commands for Calibration (Continued)
Summary of Contents for Soresen XTR 100-8.5
Page 2: ......
Page 16: ...xiv ...
Page 28: ...1 8 ...
Page 50: ...Local Operation 3 8 M370185 01 Figure 3 3 Front Panel Menu System ...
Page 93: ...Using Multiple Power Supplies M370185 01 3 51 3 ...
Page 94: ...Local Operation 3 52 M370185 01 ...
Page 128: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370185 01 ...
Page 198: ...Remote Operation 5 70 M370185 01 ...
Page 261: ...SCPI Command Tree M370185 01 A 35 A ...
Page 262: ...A 36 ...
Page 279: ...Index M370185 01 IX 3 described 3 7 3 36 number available 3 36 stored values 3 36 ...
Page 280: ...IX 4 ...