4. Turn to display
U0L 0n
or
U0L OFF
.
5. Press to commit the selected setting.
Important:
This single front panel operation affects both power on and
output enable. However, when using SCPI, there is a separate command
for each.
The SCPI command to query or enable/disable the 0 Voltage Output
Preset at power-on is:
[:]SYSTem[<channel>]:PON:VOLTage
{?|ON|OFF}
The SCPI command to query or enable/disable the 0 Voltage Output
Preset upon output enable is:
[:]SYSTem[<channel>]:PON:ENAble:VOLTage
{?|ON|OFF}
Programming Current Output Preset
To Enable/Disable automatic reset to 0 Amps:
1. Turn the rotary Adjust/Enter control to PRT and press.
2. Turn again until
Pr0 0U7P
is displayed.
3. Press to display
0U7P CUrr
.
4. Turn to display
CUrr 0n
or
Curr OFF
.
5. Press to commit the selected setting.
Important:
This single front panel operation affects both power on and
output enable. However, when using SCPI, there is a separate command
for each.
The SCPI command to query or enable/disable the 0 Current Output
Preset at power-on is:
[:]SYSTem[<channel>]:PON:CURRent
{?|ON|OFF}
The SCPI command to query or enable/disable the 0 Current Output
Preset upon output enable is:
[:]SYSTem[<channel>]:PON:ENAble:CURRent
{?|ON|OFF}
Summary of Contents for Soresen XTR 100-8.5
Page 2: ......
Page 16: ...xiv ...
Page 28: ...1 8 ...
Page 50: ...Local Operation 3 8 M370185 01 Figure 3 3 Front Panel Menu System ...
Page 93: ...Using Multiple Power Supplies M370185 01 3 51 3 ...
Page 94: ...Local Operation 3 52 M370185 01 ...
Page 128: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370185 01 ...
Page 198: ...Remote Operation 5 70 M370185 01 ...
Page 261: ...SCPI Command Tree M370185 01 A 35 A ...
Page 262: ...A 36 ...
Page 279: ...Index M370185 01 IX 3 described 3 7 3 36 number available 3 36 stored values 3 36 ...
Page 280: ...IX 4 ...