Installation Instructions:
Caution:
SurgeX®
Advanced Series Mode®
Protection is Live-Neutral
only, if the polarity indicator is illuminated when connected to
the mains please replace the plug observing correct polarity.
Mounting
SurgeX International SA Series products are shipped with four
stick-on rubber feet. These can be attached to the underside
of the unit to prevent damage to cosmetic surfaces or to
prevent the unit from slipping on a smooth surface.
Optional brackets (ordering code: SA-B) allow the unit to be
mounted permanently inside a cabinet or to any flat surface.
To attach the brackets to the SurgeX, first remove the two
screws in the middle of each side. Attach the brackets with
the same screws making sure these screws are adequately
tightened.
240 Volt Connections
SurgeX International stand alone products are designed to
operate from a 240V mains supply. 4 product lines are
available that meet major recognised global standards for load
capability and connectivity.
●
The SA-102 is rated for a maximum of 10 amps and
meets the AS3112 standard
●
The SA-132 is rated for a maximum of 13 amps and
meets the BS1363 standard
●
The SA-152 is rated for a maximum of 15 amps and
meets the BS546 standard
●
The SA-162 is rated for a maximum of 16 amps and
meets the CEE7/7 standard
Connect power to a unit by plugging the power cord into a
240V AC receptacle. Plug the equipment power cords into the
receptacles as needed to provide safe, filtered power to the
equipment.
Under no circumstances should the product be used with
an “earth lifter” or any other device which disconnects earth
from the SurgeX. Although SurgeX International products
do not shunt to earth or cause earth contamination the earth
connection is a safety mechanism. Removing the earth can
create a safety hazard and could constitute danger to life.
Indicator Lights
The green Self-Test light indicates that power is applied to
the unit and the internal surge elimination circuitry is fully
functional. If this light is not on when the unit is plugged into
the mains supply check that AC is present at the receptacle
where the unit is plugged in.
If at any point the Self-Test light should go out, first make sure
that AC is present at the receptacle where the unit is plugged
in. In the unlikely event that the light is still off once the mains
supply has been confirmed it will be necessary to return the
unit to your local SurgeX International supplier or Distributor
for repair.