TW 5250 • TW 3500 • TW 1750 Operation
Elgar TrueWave 3-7
STORAGE
(Use this menu to save/recall specific setpoint values to/from non-volatile storage)
STORE 0
RECALL 0
STARTUP [AUTO,STBY]
(Use this menu to specify if the TW will automatically source voltage at power up)
INIT RUN
INIT STANDBY
ACCESS
(Use this menu to set/clear password protection of the TW)
CODE [SET, NOT SET]
CLEAR
ENTER TO CLEAR
SET
CODE oooo
REPEAT oooo
PROG FRT [ENA, DIS]
PROG FRT ENA
PROG FRT DIS
3.8 MENU OPERATIONS
SYST
SELF TEST
Press ENT to perform a self-diagnostic test; the result is displayed as:
PASSED or FAILED
PORT
The communications parameters are set here.
GPIB ADDR (FACTORY: 25)
The GPIB address can be set here to address 1-31
CONFIG
CURRENT
The over-current mode and timing are set here.
TYPE
The current limit mode is set here
CURR SHUT (factory default)
The TW will foldback for the amount of delay set below (in
milliseconds), and then will shutdown in an over-current situation.