Operation TW 5250 • TW 3500 • TW 1750
3-14 Elgar TrueWave
3.10.3 PLACE TW INTO STANDBY MODE AFTER POWER UP
Press the Up arrow key until the display reads:
STARTUP AUTO
Press the Right arrow key. The display will read:
STARTUP STBY
Press the ENT key. The display will read:
INIT STANDBY
Press ABC/BACK repeatedly to back out of menus and return to readback display mode.
3.10.4 PLACE FRONT PANEL PROGRAM KEYS INTO DISABLED MODE
When the TW program keys are disabled, the Output key and Prog keys (VOLTAGE,
FREQUENCY/PHASE, and CURRENT/POWER) are all non-operable. In this mode the
TW will perform as last saved to system memory 0 and also can be controlled via the
SCPI interface.
Press the Up arrow key until the display reads:
ACCESS
Press the ENT key. Assuming the password is not set, the display will read:
CODE NOT SET
Press the Up arrow key. The display will read:
PROG FRT ENA
Press the Right arrow key. The display will read:
PROG FRT DIS
Press the ENT key. The display will read:
PROG FRT DIS
Press ABC/BACK repeatedly to back out of menus and return to readback display mode.