Fine Adjustments
Linear Lift AL1
Page 43 of 72
Place a wooden beam, a pallet or similar item under the platform,
in the area of the roll-off guard.
Lower the platform once again, until it rests on the pallet.
The stopper bolts on the platform are now relieved of pressure.
Loosen the locking nuts on both stopper bolts (see Figure 19).
Figure 19: Stopper Bolt
Turn the stopper bolts, to alter the angle of tilt of the platform.
Adjust the stopper bolts evenly on both sides.
Tighten the locking nuts once again.
Raise the platform slightly and remove the pallet.
Fully lower the platform once again.
Check the gap between the edge of the roll-off guard and the
ground.
Repeat the adjustment procedure, until the platform has the cor-
rect angle of tilt and the roll-off guard rests cleanly on the ground.
11.2
Transfer Plate
Movement of the transfer plate is controlled by a cable linkage. If the
cable linkage is too loosely adjusted, the transfer plate makes pre-
mature contact with the floor anchorage when the platform is raised.
If the cable linkage is too tightly adjusted, the transfer plate does not
rest on the floor anchorage when the platform is at the embarkation
/ disembarkation level.
Transfer plates that are attached to the floor anchorage rather than
to the platform do not possess a cable linkage.
In order to adjust the cable linkage: