Fine Adjustments
Page 50 of 72
Linear Lift AL1
Figure 29: Parallelism
11.6
Arrester Hooks
If the linear lift is not used for a longer period of time, the pressure in
the hydraulic cylinders will drop. The platform can then fall back,
against the rear door. When the rear door is opened, the platform
can drop down. In order to prevent this from happening, arrester
hooks are fitted to both sides of the linear lift. These engage when
the platform tilts in the direction of the rear door.
Deploy the platform.
Check the arrester hook connection points for freedom of mo-
vement (see Figure 30).
Figure 30: Arrester Hooks
If there is no freedom of movement, slacken the connection
points a little.
Clean the connection points if they are dirty.
Upper
platform
segment
Bottom
platform
segment
Connection points
Connection point
Eccentric