name or trade mark and address of the manufacturer or supplier 

 

the date of manufacture or production number 

 

recommended by the manufacturer date for an exchange if the usual 
maintenance has been performed regularly 

 

Notes to swap the battery: type or number of the recommended batteries and 
when replacing the battery is necessarily 
A visual indication to the user: "After each battery change is the 
proper operation of the smoke detector using test facility to check. " 

 
In addition instructions must be provided for the mounting location, installation and 
maintenance. In addition on the product must be the symbol for the CE marking and the 
number of EC Certificate of Conformity. The certificate of conformity 32210 may be 
requested at manufacturer. 
 

 

Re-order Smoke detectors 

 

When re-ordering smoke detectors, we would ask you, to inform us about the zone and 
the smoke detector number (on the back) so that we can encode the new smoke detector 
accordingly. If you are not sure, please send us a photo of your existing smoke 
detectors. 
 
If you want a different occupation of the zones than the standard assignment, then 
please let us know before or during the order. In the standard, the 
Zones are sequentially assigned, for example, Zone 1-5. If you want a different 
occupation, for example, in Zone 1 two detectors and Zone 2 two smoke detectors then 
we program one detector in Zone 3. 
 
 

Summary of Contents for BMS 03

Page 1: ...ee from landlines and all German mobile networks 22 12 2014 18 1 Program a smoke detector 2 2 Delete all smoke detectors 2 3 End of an alarm 3 4 Specifications headquarters 3 5 User manual smoke detec...

Page 2: ...by the unit 1 4 You now send the signal of the smoke detector twice by pressing the Test button on the smoke detector until it starts to beep and from the panel also comes a short beep Please repeat...

Page 3: ...vice In addition you have the option of the siren either ON or OFF For this purpose press the RESET button The BUZZ button is to stop only the internal signal generator Note The yellow LED on the pane...

Page 4: ...al and audible indication when battery replacement is required The minimum equipment of smoke detectors required are in the nursery sleeping area and hallway An optimum is if every room is equipped wi...

Page 5: ...a max width of 3m the allowed distance between two smoke detectors is max 15 m The distance from one end of the corridor or passage to the other must not exceed 7 5m Smoke detectors in draughty points...

Page 6: ...plied as described in the standard DIN EN 14604 will be able to work both as an individual detector as well as with other smoke detectors in an network A network requires special detectors such as tho...

Page 7: ...rooms heating and work rooms and attic In stairwells or rooms with a gallery is at least to install one smoke detector on the top of the floor Better however would be a smoke detector on each level I...

Page 8: ...ke detector is not damaged Deficiencies in these points should be removed immediately a damaged smoke detector must be replaced immediately The functional test of the smoke detector is to test the ala...

Page 9: ...w amg sicherheitstechnik de info amg sicherheitstechnik de Business hours are 9 17 clock outside this time an answering machine is running Free from landlines and all German mobile networks Summary DI...

Page 10: ...f the smoke detector using test facility to check In addition instructions must be provided for the mounting location installation and maintenance In addition on the product must be the symbol for the...