AMG2743-SF Instruction 
Sheet D15332-00 

 

Mounting Details 

The unit is designed to mount into a panel via the four mounting slots of 4.5mm x 10mm. 
 

Configuration of the RS422/485 Data Channel 

The RS422/485 data channel can operate in two modes that are set by SW2 on the main PCB. (See 
below for 

removal of the PCB

 and access to SW2) 

 
Mode 1 –  

RS485 two wire half duplex transmission. 

Mode 2 –  

RS422 four wire full duplex transmission. In this mode the RS422 output will transmit a 
tristate condition as well as logic high and logic low for systems which require bus-ing of 
the RS422 four-wire connection. 

 

MODE 

Configuration Details 

SW2 

position 1

 

SW2 

position 2

 

SW2 

position 3

 

SW2 

position 4

 

RS-422 4 wire Point-to-Point  - 
and RS-422 BUS system 

OFF OFF OFF OFF 

RS-485 2 wire BUS systems 

OFF 

ON 

ON 

ON 

 
The data input for both the RS485 and the RS422 modes detects a tri-state input condition by 
monitoring the differential voltage level across the input. A differential level below 500mV positive or 
negative will be detected as a tristate condition. A level above 500mV positive or negative will be 
detected as a logic 1 or logic zero respectively. 

It is important therefore to terminate the RS485 

bus or the RS422 input bus using 120ohms if a pre-bias is present on the RS485 or RS422 bus. 

A large number

 

of

 

third party equipment manufacturers apply a pre-bias on their RS485 bus. This pre-

bias is applied by pulling one arm of the RS485 bus high (+5 volts) and the other arm low (0 volts) 
using high value resistors within the third party equipment. In order to ensure that a tri-state condition 
is detected by the AMG2700 equipment, then these resistors should have a value above 1kohm.  

 
SW1 Switch Settings 

All SW1 switch settings are set at the factory as follows: 
 

Switch 
Position 

Description 

Setting 

1 Video 

channel 

configuration 

OFF 

2 Video 

channel 

configuration 

OFF 

3 Video 

channel 

configuration 

OFF 

Primary / Secondary Board Setting 

ON 

Dual Redundant / Not dual redundant 

OFF 

6 Not 

Used 

OFF 

7 Not 

Used 

OFF 

On board data / Separate data card 

ON 

RS232 or RS422/485 

OFF for 

RS485/422 

10 

RS232 or RS422/485 

OFF for 

RS485/422 

 
 

Removal From the Case 

Note: - 

The 2700 PCB’s are static sensitive. Handle with proper care and use normal electrostatic 

discharge (ESD) procedures. Use properly grounded protection (for example, wrist stamps) when 
handling the PCB. 
 
In order to remove the case (to access SW1 and SW2) 