28

220V/60HZ /1Phase Electric Power Unit Parts list

Item

Part#

Description

Qty.

Note

1

81400180

Rubber Pad

2

2

81400250

Start capacitor

1

3

81400200

Run Capacitor

1

4

10420148

Cap head bolt with washer

6

5

81400066

Protective cover for capacitor

2

6

81400363

Motor Connecting Shaft

1

7

80101014

Manifold Block

1

8

10209149

Lock Washer

φ6

4

9

81400276

Hex iron plug

1

10

81400259

Red Plastic Plug

1

11

85090142

Socket bolt

4

12

81400292

Gear pump

1

13

10209034

Lock Washer

φ8

2

14

81400295

Socket bolt

2

15

10209152

Ties

1

16

85090167

Magnet

1

17

81400290

Filter net

1

18

10420152

Washer

4

19

81400438

Hex Nut

4

20

81400413

Motor

1

21

81400287

Cover of Motor Terminal Box

1

22

71111230

AMGO Nameplate

1

23

81400560

Throttle valve

1

24

81400266

Relief Valve

1

25

81400284

Iron plug

1

26

81400420

Solenoid valve coil

1

27

81400423

Release valve(electrical)

1

28

81400566

Check valve

1

29

81400380

Inlet pipe

1

30

81400376

Oil return pipe

1

31

81400364

Clamp(stainless steel)

1

32

81400365

O Ring

1

33

81400263

Oil tank cap

1

34

81400327

Oil tank

1

Summary of Contents for AX-16A

Page 1: ...SCISSORS LIFT Model AX 16A Original...

Page 2: ...NTENTS Product Features and Specifications 1 Installation Requirement 2 Steps of Installation 3 Exploded View 20 Test Run 29 Operation Instruction 30 Maintenance 31 Trouble Shooting 33 Lift Disposal 3...

Page 3: ...diamond runway Integrated rear slip plates Heavy duty design fit for a wide range of vehicle car to van and light truck Optional Jack with hand pump air operated hydraulic pump Optional Turnplate MOD...

Page 4: ...MENT A TOOLS REQUIRED Rotary Hammer Drill 19 10 4 Hammer Level Bar English Spanner 12 Ratchet Spanner With Socket 28 Wrench Set 8 14 15 17 19 Carpenter s Chalk Screw Sets Tape Measure 7 5m Pliers Lock...

Page 5: ...and must be dried completely before the installation 2 Concrete must be in good condition and must be of test strength 3 000psi 210kg cm minimum 3 Floors must be level and no cracks D POWER SUPPLY Th...

Page 6: ...r in direction the oil hose cover is put to right angle The control cabinet can also be installed to the right of car in direction The control cabinet is installed at the left of car in direction The...

Page 7: ...ount installation foundation Fig 5 2 3 Illustration for flush mount installation Fig 6 Fig 5 Fig 6 47 46 45 44A 44B 44C A A 100 PVC Tube Hydraulic system limit switch Air source input 100 PVC Tube 4 P...

Page 8: ...mp Etc See Fig 7 2 Move aside the lift with fork lift or hoist and open the outer packing carefully 2 1 Parts for on surface installation See Fig 8 2 2 Parts for flush mount installation See Fig 9 Not...

Page 9: ...ts according to the part list See Fig 10 4 Check the parts of the parts bag according to the parts bag list 4 1 Parts bag for on surface installation See Fig 11 4 2 Parts bag for flush mount installat...

Page 10: ...ontrol cabinet can be installed on the left or right according to the site 2 Connecting the oil hose and air line 2 1 Control cabinet installed in the left of the car in direction See Fig 14 PII PI Fi...

Page 11: ...n direction See Fig 15 3 Install the oil water separator See Fig 16 Connect to the A of Air solenoid valve Fig 15 Fig 16 Connecting the air source by the oil water separator 69 12 11 12 8 70 67 83 68...

Page 12: ...cording to the Wiring diagram See Fig 18 Clockwise to increase the air pressure Counter clockwise to reduce the air pressure Adjust the air pressure to 0 8MPa Adjust the air pressure to 0 8MPa Fig 17...

Page 13: ...LOCK Duplex 3 Breaker FU2 1P 13 Push button Down Triple 4 Breaker FU3 1P 14 Lower Alarm button Pass Duplex 5 AC contactor KM 24V AC 15 Buzzer H 24VAC 6 Time relay KT 24V AC 16 Transformer TC 24VAC 7...

Page 14: ...downward screw when lower to the lowest position tighten nut finally 2 Install anchor bolts 2 1 Raise the lift to 1000mm then drill holes to install the anchor bolts See Fig 22 Using the anchor bolt...

Page 15: ...ratchet spanner See Fig 23 Note The torque of anchor bolt is 150N m the length inside ground of anchor bolt must be over 3 1 2 F Install platform runway connecting bar Install Limit rod See Fig 24 Dri...

Page 16: ...he oil hose cover See Fig 25 2 Install the oil hose cover See Fig 26 Fig 26 Fig 25 90 89 Type the expansion colloidal screw Fastening by Install the steel screw Cleaning Drilling with 4 driller Using...

Page 17: ...15 H Install optional parts of air line kit see Fig 27 Fig 27 90 air line Fitting Connect Air Source 12 30...

Page 18: ...16 1 Install air line kit 1 1 Connect the air line fittings with 8 6 black air line as following photo The length of air line can be cut accordingly See Fig 28 Fig 28 A B C D E F G a...

Page 19: ...way fitting from oil water separator then pass through black air line 8 6 to control cabinet and connect with screw fitting 1 3 Through black air line 8 6 to the hole at the base and fixing slot of ou...

Page 20: ...View b 1 4 With Two way valve separate the air source into two ways and connect with rolling jack separately 1 5 Install quick female fitting then connect it with male air line 1 6 Install quick femal...

Page 21: ...T fitting 1 101 1061K090 C shape Quick female fitting 2 97 1061K094 90 bend fitting 2 102 10540009 8 6 17500mm Air line 1 98 1061K092 Hex nut M14 2 103 10420146 Quick Male fitting 2 99 10430010 14 Was...

Page 22: ...20 IV EXPLODED VIEW MODEL AX 16A Fig 31 Optional turnplate set turnplate adjusting block to both side when installation 93 75 74 94 98...

Page 23: ...8 19 11520024A Connecting Pin For Scissors 4 19A 10610019 Self locking nut M30 3 5 4 20 11570002 Offside Platform 1 20A 10610108 Washer 44 30 5 2 4 21 10510041 Limit Switch Assy 1 21A 10530023 Washer...

Page 24: ...ble straight 1 60 10570022 01 Oil Hose No 1 4 5960mm straight 90 1 61 10570023 01 Oil Hose No 1 4 6100mm double straight 1 62 10570024 01 Oil Hose No 1 4 6300mm double straight 1 63 10510023 Straight...

Page 25: ...0mm 1 87 11540029 Oil Hose Cover 1 88 10620065 Shim 2mm 20 88A 10201090 Shim 1mm 20 89 10620070 Colloidal 6 36 90 10620069 Wood Screw M4 30 36 91 10570500 Parts box On surface installation 1 92 105705...

Page 26: ...24 4 1 CYLINDERS EXPLODED VIEW 520028B 520017B Fig 32 Add grease to lubricate regularly Add grease to lubricate regularly...

Page 27: ...0055 Y Ring OSI 105 120 9 2 11 11 11520045 Piston Main 1 11 12 10520049 Set Screw 1 11 13 10520047 Hex Nut 1 11 14 10530009 Burst valve 2 Parts For Secondly Cylinder 27 1 11510010B Secondly Cylinder 1...

Page 28: ...Control Panel 1 12 6 41010217 Power Switch QS 1 12 7 1152K007D Cabinet Body 1 12 8 10420167C Air line 6 8 200mm 2 12 9 1061K110 Straight Fitting 6 8 1 4 inner thread screw 1 12 10 10209145 Cap Head B...

Page 29: ...head bolt M4 8 19 12 21 10420135 Timer Relay Base 2 12 22 10420141 Intermediate Relay KA 1 12 23 10420083 Timer Relay KT 1 12 24 10420084A AC Contactor KM 1 12 25 10420142 Down Alarm Button Pass 1 12...

Page 30: ...12 81400292 Gear pump 1 13 10209034 Lock Washer 8 2 14 81400295 Socket bolt 2 15 10209152 Ties 1 16 85090167 Magnet 1 17 81400290 Filter net 1 18 10420152 Washer 4 19 81400438 Hex Nut 4 20 81400413 M...

Page 31: ...button to start filling oil in the cylinder until the machine starts to lift at this time push Down and Pass button about 5 seconds while hearing the buzzer sound and the sounds of inside air coming...

Page 32: ...e the safety device is locked in the same height To lower vehicle 1 Be sure clear of around and under the lift only leaving operator in lift area 2 Push the button Down the lift is lowered continually...

Page 33: ...eason DO NOT use the lift until the bolt has been replaced 3 Make a visual inspection of all hydraulic hoses lines for possible wear or leakage 4 Adjusting the lifting level on both platforms 5 Lubric...

Page 34: ...ld be replaced regularly during using Replace the hydraulic oil 3 months after the first installation Replace the hydraulic oil once a year afterwards 3 Make at least one full trip raising and lowerin...

Page 35: ...replace 5 Repair or Replace Lift does not stay up 1 Hydraulic Solenoid valve out of operation 2 Relief valve or check valve leakage 3 Cylinder or fittings leaks Repair or replace Lift raised slowly 1...

Page 36: ...34 it should follow local laws and regulations AMGO HYDRAULIC CORPORATION Tel 803 505 6410 Fax 803 505 6410 Manual No 72257403 Revised date 2022 05 1931 Jo Rogers Blvd Manning South Carolina USA...