4.4
Safety information
the outer surfaces, door, handles, glass panel
and flue pipe will become hot during operation!
Appropriate gloves precautions must be taken.
Option 1.
External combustion air supply from
below.
Option 2.
External combustion air supply rear.
4.5 Installation instructions
The standard product is delivered assembled
ready for connection and must be sealed to the
existing chimney using a short, straight, horizontal
connecting piece. the stoves can be connected
either from above or from the rear.
Building and fire regulations must be observed.
Contact a registered installer for advice in
advance.
1.6 Combustion air supply
Before operating the stove, an adequate supply of
air for combustion must be ensured and the room
must be well ventilated.
Stoves are usually operated as non-room sealed
heating appliances which draw combustion air
from the room where the appliance is fitted. For
this reason, it must be ensured that the room is
well ventilated
Tight-closing windows and doors can limit the
supply of combustion air with adverse effects on
the flue draught. This can be detrimental to health
and possibly compromise safety. Air consumers
such as extractor fans or fans installed together
with heating appliances in the same room or room
air connection can adversely effect the function of
the stove. These must not be operated at the
same time as the stove. An air balance must be
established to ensure that the stove functions
perfectly
Combustion air can also be provided directly via a
duct from outside, or indirectly via a vent in the
outer wall of the room where the stove is to be
placed. The amount of combustion air used for
combustion
is
approximately
25
m3/h
5. Chimney and flue pipe
Chimney dimensioning takes place in accordance with EN 13384-1 and 2 or the country-specific
regulations. The chimney must have the temperature class T400 and an effective height of minimum 4.5
m. The chimney cross-section must be adapted to the stove.
Carefully check that the chimney is sealed and that there is no leakage around soot hatches and flue
connections. Maximum chimney weight loading on the stove 120 kg.
Note that a flue with sharp bends and horizontal routing reduces the draught in the chimney. The stove
requires a draft in the chimney of at least –12 Pa. Maximum horizontal flue is 1 m, on the condition that
the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot
hatches must be easily accessible
GB25
Summary of Contents for 5E
Page 1: ...Operating Installation Instruction www AMIFires com 5E 5E LS AMI Fire HiFlame ...
Page 3: ...Fonctionnement et installation Directive Www amifires com 5E 5E LS AMI Fire HiFlame FR3 ...
Page 18: ...Operating Installation Instruction www AMIFires com 5E 5E LS GB18 AMI Fire HiFlame ...
Page 33: ...Bedienung und Installation DIE RICHTLINIE Www amifires com 5E 5E LS AMI Fire HiFlame DK33 ...
Page 48: ...Werking en installatie Richtlijnen Www amifires com 5E 5E LS AMI Fire HiFlame NL48 ...