Installation Guide & Owner’s Manual  – Under-the-Counter RO & Alkaline Drinking Water System 

 

Copyright © 2019 WaterAnywhere. 

All Rights Reserved.

 

Page 14 

 

 

System 

Maintenance          

 Notice:

 

If your RO system is connected to an icemaker or other equipment, you must turn off 
the connection to the equipment before performing any maintenance. 

 

Membrane Replacement Instructions 

The membrane should be replaced every 1-2 years, depending on the water quality. 

 
Before starting, shut off the cold water supply to the unit.   Lift the handle on the faucet to drain out the storage 
tank completely and allow the system to stand for 10 minutes in order to fully decompress the tank.   Leave the 
faucet open until the membrane change is complete. 

 

1.  Unscrew the fitting to the cap of the membrane housing.  Use the membrane wrench if the cap is too tight. 
2.  Using pliers, pull out the old membrane from the housing.     
3.  Remove the new membrane from its bag.  
4.  Insert the membrane in the housing in the same direction as the old membrane.  
5.  Push the membrane firmly into the housing until it seats on the far end.  
6.  Screw the housing cap back on, making sure the o-ring is positioned correctly.  
7.  Screw the fitting (with tubing) back onto the housing.  
8.  The system is ready. Turn on the water supply. Check for any leaks. 
9.  Drain the first two tanks of water before drinking. 

Filter Replacement Instructions 

All pre and post-filters should be replaced every 3-6 months.

 

 
Before starting, shut off cold water supply to unit.   Lift the handle on the faucet to drain out the storage tank 
completely and allow the system to stand for 10 minutes in order to fully decompress the tank, reserving some 
of the RO water to use to rinse the filter housings.   Leave the faucet open until the filter change is complete. 

 

1.  Remove pre-filters from filter housings.  Use a filter wrench if the housings are too tight.  
2.  Discard used filters, but save o-rings for re-use.  
3.  Clean inside of all housings with a mild soap solution, and then rinse with RO water.  
4.  Lubricate the o-ring and replace in filter housing. 
5.  Insert the new filters into the appropriate housings and replace the housings onto the system. 
6.  Disconnect the post-filters by removing the fittings on either end.  Replace with new post-filter and re-use 

the existing fittings.   

7.  Follow the normal Start-up Procedures.  (Drain the first tank of water after changing the filters before 

drinking.) 

Sanitizing 

We recommend sanitizing the system at least once a year.  This can be done while changing your filters. Shut 
down the system.   If you have an icemaker hook-up installed, be sure the ball valve in the line to the 
refrigerator is in the closed position during this procedure.   Open the faucet to drain the system, including the 
tank.  Remove the pre-filter cartridges and RO Membrane from the system, leaving the old post-filter cartridges 
in place.   Wash the internal filter housing & membrane housing areas with warm soapy water and rinse well to 
remove the soap.  Pour about ¼ teaspoon of Hydrogen Peroxide or household bleach into each filter housing 
and replace housings on the RO system. Open the feed water valve and open the RO faucet until water flows 
freely from the spout.  Close the faucet and hold the solution in the system for a minimum of 10 minutes. 
Drain the tank completely, close the faucet to allow tank to fill again, and then drain again.  Replace filters and 
membrane as indicated in the replacement instructions.  The post filter should be changed after sanitizing the 
system. 

Summary of Contents for AAA-N50W

Page 1: ...www wateranywhere com 760 727 1652 sales wateranywhere com Document ID AAAN50W Revision 05 13 20 RO Alkaline Drinking Water System Installation Guide Owner s Manual AAA N50W ...

Page 2: ...ane substantially reduces the total dissolved solids TDS from the water including arsenic barium cadmium chromium hexavalent chromium trivalent copper turbidity fluoride lead radium 226 228 and selenium while washing the rejected contaminants down the drain The treated water is directed to the storage tank Stage 5 Post Carbon Filter Replace every 3 6 months The last stage of filtration occurs as t...

Page 3: ...ings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step 3 Drain Saddle Installation 9 Step 4 System Feed Line Installation 10 Step 5 Installing the RO Storage Tank 11 Additional Point of Use Connection Optional 11 System Mounting 12 Turning the System On for ...

Page 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically unsafe or of unknown quality Never use hot water or allow the unit to freeze Incorrect installation or operation will void the warranty Excessive incoming water pressure can cause leaks flooding and pro...

Page 5: ...h the RO Membrane E Four way Valve F In Line Cartridge with Activated Carbon G Alkaline Mineral Cartridge H Flow Restrictor I Tank Valve J Tank K Faucet 1 Clean Water Outlet 2 Pollutants Outlet 3 Water Supply to the 4 way valve from the elbow connector OUT in the third housing 4 Clean water supply to the 4 way valve through the membrane 5 Water outlet from the valve to the membrane 6 Clean water o...

Page 6: ...her hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane see conditions for operation To assure you are using the cold water line turn on both the hot and cold faucet After the water is warm to the touch feel the pipes under the sink It will be easy to iden...

Page 7: ...d Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause leaks Remove blue locking clip from fitting before installing tubing Push down on the fitting collet and remove the plug Keep the clip The plug may be discarded Push the tubing into the fitting to the pip...

Page 8: ... at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a larger hole of to allow for the additional tubing connections required Stainless Steel Sinks Begin by placing a piece of masking tape or duct tape on the determined location where the hole is to be drilled ...

Page 9: ...p and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threading on the locking nut 7 Check the orientation and alignment of the faucet and washers adjust as necessary then use a wrench to tighten the locking nut securely Notice Do not overtighten fittings Install th...

Page 10: ... with the drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the other side of the drain pipe Install the Drain Clamp Apply the foam gasket inside the front half of the drain saddle Punch out the cut out hole in the center of the pad remove the adhesive back...

Page 11: ...pressure from the lines Assemble the Ball Valve Adapter Kit Identify your line size and use the appropriate feed adapter 3 8 or 1 2 The extra feed adapter is not needed Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve into the adapter Install the Feed Adapter into the Cold Water Supply Wrap the slip joint adapter with Teflon tape approximately 3 wrap...

Page 12: ... all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic taste in the water or ice and cause the copper tubing to develop pinhole leaks over time An additional connection may be made to other equipment such as an icemaker refrigerator coffeemaker or other equi...

Page 13: ...seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the connection Open the product water faucet and let the water flow until all the air has been expelled from the system This will take about an hour Close the product water faucet In 30 minutes check the system ...

Page 14: ...using Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R2068QC 50 GPD Flow Restrictor H R1000QC 100 GPD Flow Restrictor H J2021KW Clip Membrane Housing to In line Filter H J2025PW Clip Membrane Housing to Bracket Part Image H T5000 Faucet Non Airgap Long Reach H V1050W QC Auto Shut Off Valve H S3200TV Tank Shut Off Valve H V1009 Feed Valve and Adapter H D3...

Page 15: ...ng some of the RO water to use to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filters but save o rings for re use 3 Clean inside of all housings with a mild soap solution and then rinse with RO water 4 Lubricate the o ring and replace in filter housing ...

Page 16: ...p may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77ºF and 60psi Water production will decrease approximately 1 5 for each degree that your incoming water is below 77ºF It may be necessary to change to a higher flow membrane and flow restrictor Storage tank pressure is too low Check pressure with gauge and refill to maximum 8 psi Note Tank...

Page 17: ...__________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________...

Page 18: ...__________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________...

Page 19: ...l not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR PROSPECTIVE PROFITS OR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES NOR SHALL RECOVERY OF ANY KIND AGAINST SELLER BE GREATER IN AMOUNT THAT THE PURCHASE PRICE OF THE SPECIFIC GOODS SOLD AND CAUSING THE ...

Page 20: ...rately Record Date RFK N50 50 Replacement Membrane Filter Pack With 50 GPD Membrane Includes 1 H F1005CF 5 Micron Sediment Prefilter Stage 1 2 H F2510AC Carbon Block Pre filters Stages 2 3 1 M T1812A50 50 GPD RO Membrane Stage 4 1 H F10GAC 14 Carbon Post Filter Stage 5 1 H F10ALK 14 Alkaline Mineral Filter Stage 6 RFK N Replacement Filter Pack Includes 1 H F1005CF 5 Micron Sediment Prefilter Stage...

Reviews: