DISCOVER YOUR DIGITAL POTENTIAL
5
S
PECIFICATIONS
I/O
•
Analog input x 4: 0-2.5V, 0-10V / 4-20mA (SW configurable)
•
Digital input
•
RS485 Half-Duplex
Communication
•
4G LTE cellular cloud connectivity
•
900MHz RF star-network configuration for multiple pumps
connectivity
•
BLE
•
GPS
Measurements
•
3-Axis vibration monitoring [Inch/Sec]
•
Temperature ±5° [°F]
•
Battery voltage [V]
EDGE computing
•
Radial velocity RMS
•
Axial velocity RMS
•
3-Axis velocity FFT @ Five selected frequencies
o
Where x = rotation freq. ex. 1x, 2x, 3x, 7x, 10x
•
Rotation velocity [RPM]
•
Operational hours
Notifications
•
Axis velocity RMS threshold cross
•
Radial velocity RMS threshold cross
•
Velocity amplitude threshold cross in any of the FFT selected
frequencies
•
Operational time threshold cross
•
Temperature threshold cross
•
Analog measurement threshold cross
•
Digital input changes or flow frequency threshold cross
Operation modes
•
Battery: 1 yr. @ 4 sample/hour and 2 cloud updates per day
•
External DC power: 9..24VDC; up to 20 sample/hour and 8 cloud
updates per day
User interface
•
Internet browser
•
Mobile apps: IoS and Android using BLE for on-site offline device
connectivity
Dimension & build
•
3.4”x3.4”x1.9”
•
Robust glass filled PP enclosure IP65 comply
•
Mounting screws 4x #8-32 x1 inch long
Standards
•
FCC Part 15 (see label)
•
RoHS comply
Environmental conditions
•
Temperature: -22°F/+158°F