Outdoor LoRa Data Logger
29
1.6.7 Device Mount and Screw Back the Top Cover
The OOT550 series product has to be configured with a Windows configuration tool. Just find out a PC/NB with
an available USB port, and plug in the USB cable into it.
After you finished all the software configurations, you are ready to free the OOT550 and make it operate as
expected. You have to take the following actions for it
.
1.
Power Off the OOT550, and remove the USB cable.
2.
Mount the OOT550 base enclosure on the planned location.
3.
Make sure all the wiring cables are running in position through the M16 connectors;
4.
Fasten tightly the external parts on the M16 connectors, holding the internal cables to
prevent from twisted along with the cable gland with care.
5.
Power On the OOT550, and wait until the Status LED becomes BLUE light flashing to
make sure it booted up without problem.
6.
Screw back the Top cover with care. Make sure the surrounding rubber pad is in position
everywhere to keep the IP65 performance for water and dust proof.