16
INSTALLATION
The procedure for changing the gas type
Flame
Conversion from LPG
to natural gas
Conversion from natural
gas to LPG
full flame
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
2.Gently tighten the adju-
sting screw and check the
flame size.
Burner
small flame
hob
oven
full flame
1.Replace burner nozzle with
the appropriate nozzle accor-
ding to the table.
2.Gently tighten the adjusting
screw and adjust the flame.
The temperature in the oven
should be 150
O
C.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and adjust the
flame. The temperature in
the oven should be 150
O
C.
small flame
Surface burners applied do not require adjust-
ment of primary air. A correct flame has dis
-
tinct internal cones of blue and green colour.
A short, humming flame or long, yellow and
smoking one, without clearly outlined cones,
shows improper quality of gas in the house-
hold piping or a damaged or soiled burner.
In order to check a flame, heat a burner for
around 10 minutes with a full flame, and next
turn the valve knob to the economical flame
position. The flame should not go out or jump
onto the nozzles.
In cookers with a safety device, a knob with
a surface burner safety valve is used, fig.
Knobs should be adjusted with the burner
switched on and set to the economical flame
position, using an adjustment screwdriver of
the 2.5 mm size.
Caution!
After adjustment is completed, place
a label indicating the type of gas to
which the cooker is now adapted.
A professional installer must adjust the small
flame on-site in your home. The adjustment
depends on the type of gas and its pressure.
Adjustment
valve