16
INSTALLATION
Burner of DEfENDI type
The procedure for changing the gas type
flame
Conversion from LPG
to natural gas
Conversion from natural
gas to LPG
full flame
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
2.Gently tighten the adju-
sting screw and check the
flame size.
Burner
small flame
hob
oven
full flame
1.Replace burner nozzle with
the appropriate nozzle accor-
ding to the table.
2.Gently tighten the adjusting
screw and adjust the flame.
The temperature in the oven
should be 150
O
C.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and adjust the
flame. The temperature in
the oven should be 150
O
C.
small flame
In order to perform adjusting operations, take
off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the
oven chamber floor.
Exchange of a burner noz-
zle – unscrew the nozzle
with special socket span-
ner No 7 and replace with
a new one according to a
type of gas (see tables).
Type of gas
Burner
auxiliary
gas
injector
diameter
[mm]
medium
gas injector diameter [mm]
large
gas injector diameter [mm]
oven
gas injector
diameter
[mm]
nominal
thermal
power
1,00 kW
nominal
thermal
power
1,40 kW
nominal
thermal
power
1,75 kW
nominal
thermal
power
2,40 kW
nominal
thermal
power
3,00 kW
nominal
thermal
power
2,80 kW
G20 2H 20 mbar
0,77
0,86
0,97
1,12
1,29
1,30
G30/31 3+ 28-30/37
mbar
0,50
0,60
0,65
0,78
0,87
0,84