When the extractor is to be
installed above an Amica hob,
the minimum distance between
the hob and extractor must
exceed 550mm.
If the instructions provided
with another brand of gas hob
state that the required distance
between the hob and extractor
must be greater than 550mm,
then that is the distance that
should be observed; this is a
legal requirement and may lead
to your hob being disconnected
from the gas supply and the
installation being reported under
RIDDOR.
Note:
The height should be measured from the top of the burners.
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH
THE GAS HOB, THE MINIMUM DISTANCE BETWEEN THE HOB
AND EXTRACTOR MUST BE AT LEAST 760mm.
The width of any hob must not be greater than the width of the
extractor installed above it.
Fig. 7
AEP60BL / AEP90BL
A
128mm
B
218mm
C
119mm
D
75mm
A
B
D
C
Gas: 550mm minimum
Electric: 550mm minimum