Minimum distances from the heat
sources
- from the electric gas and other
ovens - 30 mm,
- from oil or coal fired ovens - 300
mm,
- from built-in ovens - 50 mm
If there is no possibility of ensuring the above- men-
tioned distances, provide an appropriate insulation
board.
The rear wall of the refrigerator, in particu
-
lar, the condenser and other elements of
the cooling system must not contact other
elements, which may damage them, (e.g.
central heating pipes and the water supply
pipes).
It is forbidden to readjust or modify any
parts of the unit. It is crucial not to damage
the capillary tube visible in the compressor
recess. The tube may not be bent, straigh
-
tened or wound.
If the capillary tube is damaged by the user
the guarantee will be void (fig. 5).
Mains connection
l
Before the appliance is connected to the
mains, set the adjustment knob to the "OFF"
/ “0” position.
l
This appliance should be connected to AC 230V
50Hz supply socket. The socket must be fitted
properly, and must be supplied with an earthing
conduit and a 10A fuse.
l
It is a legal requirement that the appliance is pro-
perly earthed. The manufacturer will not be held
liable for any damage or injury which may result
from the failure to fulfil this requirement.
Do not use adapters, multiple sockets and
two-wire extension leads. If it is necessary
to use the extension lead, it must be equ-
ipped with a protection ring and a single
socket and must have a VDE/GS safety
certificate.
l
If an extension lead is used (with a protec- tion ring
and safety certificate), its socket must be located
at a safe distance, away from the sinks, and must
not be in a place where it could be flooded by
water or waste water.
l
See the type plate at the lower part of the internal
wall of the appliance for detailed specifica- tions.
Disconnecting the mains
l
Make sure the appliance can be easily disconnec-
ted from the mains, either by pulling the plug out
of the mains socket, or by switching the two-pole
switch off (fig. 6).
l
On the exterior surface of the product may be a
protective foil, this foils should be removed.
l
Make sure the appliance is placed in a horizontal
position by screwing in the 2 adju- stable front legs
(fig. 3)
l
In order to ensure easy opening of the door,
the distance between the side wall of the
appliance (from the side of the door hinges),
and the wall should amount to: 70 mm. (for
appliances with external handle) and 50 mm
(for appliances with recessed handle).
l
Ensure adequate ventilation of the room and free
air circulation from all sides of the appliance (fig.
4).