background image

INSTRUCTION MANUAL  

EN

PVG4.0ZpZtR / PGX 6610

PVG4.1ZpZtRC / PGXZ 6611

Summary of Contents for PGX 6610

Page 1: ...INSTRUCTION MANUAL EN PVG4 0ZpZtR PGX 6610 PVG4 1ZpZtRC PGXZ 6611 ...

Page 2: ... times for reference Obse rve the instructions contained herein to prevent accidents Note Do not start to use the appliance before you have read and understood the instructions This equipment has been designed solely as a cooking appliance It is strictly prohibited to use it for any other purpose e g heating Using the appliance for other purposes can be dangerous The manufacturer reserves the righ...

Page 3: ...odel identifier PGX 6610 PGXZ 6611 PVG4 0ZpZtR PVG4 1ZpZtRC 1106021 1106020 Hob type electric gas gas electric O V O O V O Number of gas burners 4 4 Energy efficiency for each gas burner EE gas burner FL 53 5 53 5 RL 53 5 53 5 RR 53 5 53 5 FR 53 5 53 5 C Energy efficiency of gas hob EE gas hob 53 5 53 5 In order to determine compliance with the eco design requirements the measurement methods and c...

Page 4: ...t of reach of children UNPACKING DISPOSAL OF THE APPLIANCE Old appliances should not simply be di sposed of with normal household waste but should be delivered to a collection and recycling centre for electric and electronic equipment A symbol shown on the product the instruction manual or the packaging shows that it is suitable for recycling Materials used inside the appliance are recyclable and ...

Page 5: ...ough some simple safety when cooking is generally observed it is worth reading through the following points to ensure that your hob is operated as safely as possible at all times to prevent any accidents As a responsible company we feel it is very important to maintain a very high level of safety and to make this section as clear and highlighted as possible Should you have any additional concerns ...

Page 6: ... overall maximum load of a pan that is to be placed over the entire grate is 10 kg Do not place a single pan over two burners at the same time Do not impact the burners and knobs It is prohibited to modify or repair the hob by persons who do not possess appropriate training and qualifications Do not set the burner knobs open before you have stricken the match or the ignition appliance Do not extin...

Page 7: ...rating plate The cooker is equipped with a pipe terminal 1 2 ISO 228 1 PVG4 0ZpZtR PGX 6610 1 1 2 3 4 5 3 5 4 4 4 1 2 3 4 5 3 5 4 4 4 1 2 3 surface burners 4 surface burner knobs 5 grid TECHNICAL DATA heigh 87 mm depth 500 mm width 580 mm weight of the cooker 8 5 kg The cooker is equipped with burners 1 WOK burner heat load 2 8 kW 2 small burner heat load 1 kW 3 medium burners heat load 1 8 kW App...

Page 8: ...entilation system routed to the outside of the building l The minimum distance between the burners and the hood exhaust should be 750 mm see fig 3 GUIDE TO THE COOKTOP EN 3 INSTALLATION Installation of the cooktop l Prepare the work top cut out as shown in the diagram see fig 5 l Remember to maintain the minimum safety distances to combustible surfaces below the cooktop of 130 mm l Fix the tape in...

Page 9: ... must be observed The cooktop is equipped with an R1 2 connecting pipe for gas connection If the appliance is intended for use with LPG propane butane a Ø 8 x 1 mm hose coupling is threaded onto the connector Make sure the gas connecting pipe does not come in contact with the metal components of the cooktop All the couplings and joints must be tightly sealed Note After connecting the appliance che...

Page 10: ... conditions at a licensed gas fitter service NOTE The cooktops delivered by the supplier come with the burners which are suitable for burning the type of gas which is quoted in the type plate and in the guarantee certificate The type plate is fitted at the bottom panel of the appliance The following must be carried out if converting to another gas type is required l nozzles must be replaced see as...

Page 11: ...s follows l Up to 60 per cent savings when proper pots are used l Up to 60 per cent savings when the unit is operated correctly and the suitable flame size is chosen It is a prerequisite for efficient and energy saving operation of the cooktop that the burners are kept clean at all times in particular the flame slots and nozzles Suitable pans Selection of vessels Bear in mind that the diameter of ...

Page 12: ...the knobs equipped with the leak prtection What to do if surplus gas leak occurs 1 gas network 2 gas cut off valve A valve ON B valve OFF 10 11 In any emergency proceed as follows l turn the burners off l set the cut off valve OFF see fig 9 B l ventilate the kitchen l report the unit for repair at a service department of a licensed and authorised repair shop l refrain from using the appliance unti...

Page 13: ...ol elements and units of the cooktop Upon expiration of the warranty service department shall be ordered technical inspections of the appliance at least once every two years l All operation faults must be repaired l Cooktop units shall be maintained according to the maintenance schedule GUARANTEE Guarantee Guarantee service will be granted as per the Guarantee Certificate The manufacturer cannot b...

Page 14: ...lots 3 Igniter does not work power cut check the home power fuse repla ce if needed gas supply break open gas cut off valve contaminated caked igniter clean the igniter control knob released too soon hold the control knob depressed until the flame goes on and persists 4 Burner extinguishes control knob released too soon hold the control knob depressed until the flame goes on and persists Manufactu...

Page 15: ...15 ...

Page 16: ...Amica Wronki S A ul Mickiewicza 52 64 510 Wronki tel 67 25 46 100 fax 67 25 40 320 www amica com pl IO 00611 6 07 2015 ...