35
OPERATION
Using the hob equipped with igniter knobs
(
marked
Zp)
Steps:
• push down the knob of a selected burner until you feel resistance and turn left to
the "large flame" position
• hold the knob until gas ignites
• once flame ignites, release the knob and adjust flame size.
Using the hob equipped with a flame-failure cut-off device (
"
Zt
" model)
Fig.
In hobs equipped with a flame‑failure cut‑off device, hold the pushed down knob in
the "large flame" position for approximately 10 seconds to activate the a flame‑
failure device.
Repeat the above step if flame does not ignite.
If flame is extinguished, the flame-failure device will cut off gas supply within
about 60 seconds.
You can open and control the gas supply to the burners using knobs with
flame-failure cut-off device (Zt models).