background image

1

CS-SLVP-ADA-00

Accessory Basket with Capsule Neuron 2

Quick Installation and Maintenance Instructions

Medical Facility Responsibility 

!

WARNING:

 It is the responsibility of the end user to ensure all aspects of installation are covered by following the full manual found at  

https://www.amico.com/products/equipment-mounts/patient-monitor/capsule-monitor-mounts/capsule-neuron-mounts

.

Installation Tools

1x #2 Phillips Head Screwdriver

1x #3 Phillips Head Screwdriver

Hex Key: 1/8"

 NOTE:

 Tools for installation not provided by Amico Accessories. Verify the weight of the monitor to be mounted. This product is rated at 20 lbs 

total, including 5 lbs in the basket. The 

CAPSULE NEURON 2

 must be mounted with the 

NIBP PACK

* as shown in 

Figure 2

. The 

CAPSULE 

NEURON 2

 can only be mounted to 

CS-SLVP-ADA-00

 without the 

NIBP PACK

 in a non-flush configuration. 

Mounting to AHM-_4-_/SSM-_4-_

 Insert  3x 

FLAT HEAD SCREWS

 through the top of the 

MOUNTING PLATE

 and into the 

DISK

 as shown in 

Figure 1

 using a 1/8" Hex Key/bit. Use the provided 3/16" Hex Key to 

tighten and secure. 

MOUNTING PLATE

[X-CS-NRN2-BSK-PLT]

(A PART OF CS-SLVP-ADA-00)

3x 

FLAT HEAD SCREWS 

[H-FHCS-1032-58]

DISK

 [MON-SWIV-DISK-T]

(A PART OF AHM-_4-_ OR SSM-_4-_)

Installation Tools (not provided)

Mounting to AHM-_4-_/SSM-_4-_

1.  Insert 3 x FLAT HEAD SCREWS through top of MOUNTING 

PLATE and into DISK as shown in (

Figure 1)

 below using 

a 1/8" hex key/bit. Use the provided 3/16" hex key to 
lighten and secure. 

WARNING:

 It is the responsibility of the end user to ensure all aspects of installation are covered by following the full manual found at 

 http://www.amico.com/products/capsule-neuron-mounts.

NOTE:

 Tools for installation not provided by Amico Accessories. Verify the weight of the monitor to be mounted. This product is rated at 20 lbs

 TOTAL

including 5 lbs in the basket. The

 CAPSULE NEURON 2

 must be mounted with the 

NIBP PACK* 

as shown in

 (Figure 2)

. The C

APSULE NEURON 2

 can only be 

mounted to 

CS-SLVP-ADA-00

 without the 

NIBP PACK

 in a non-flush configuration. 

Installation Reference

CAPSULE NEURON 2  

(NOT PRODVIDED)

3 X

 

FLAT HEAD SCREW

[H-FHCS-1032-58]

Accessory Mounting

Accessory Basket  

with Capsule Neuron 2

CS-SLVP-ADA-00

Quick Setup to Attach Accessory Basket to Amico Mount

For use with Capsule Neuron 2 (Vitals Plus)

1.  Insert 4 x 

PAN HEAD SCREWS

 through 4 x 

LOCK WASHERS

 

through the back of the

 MOUNTING PLATE 

and into the 

device

 (CAPSULE NEURON 2 AND NIBP PACK*)

 as shown 

below. 

MOUNTING PLATE

[X-CS-NRN2-BSK-PLT]

(A PART OF CS-SLVP-ADA-00)

DISK [MON-SWIV-DISK-T]

(A PART OF AHM-_4-_  

OR SSM-_4-_)

*NIBP PACK  

(NOT PRODVIDED)

4 X

LOCK WASHER

[H-WLM-M4]

4 X

PAN HEAD SCREW

[H-PHMS-M4-14]

MOUTING PLATE  

[X-CS-NRN2-BSK-PLT]

(PART OF CS-SLVP-ADA-00)

Hex Key: 1/8"

Phillips Head Screwdrivers: #2, #3

Hex Key: 1/8"

CS-SLVP-ADA-00

 

Figure 1

For Use with Capsule Neuron 2 (Vitals Plus)

 Insert  4x 

PAN HEAD SCREWS

 through 4x 

LOCK WASHERS

 through the back of the 

MOUNTING PLATE

 and into the device (

CAPSULE NEURON 2 

and

 NIBP PACK*

) as shown 

in 

Figure 2

.

 

MOUNTING PLATE  

[X-CS-NRN2-BSK-PLT]

(PART OF CS-SLVP-ADA-00)

4x

LOCK WASHERS

[H-WLM-M4]

4x

PAN HEAD SCREWS

[H-PHMS-M4-14]

*NIBP PACK  

(NOT PROVIDED)

CAPSULE NEURON 2  

(NOT PROVIDED)

Installation Tools (not provided)

Mounting to AHM-_4-_/SSM-_4-_

1.  Insert 3 x FLAT HEAD SCREWS through top of MOUNTING 

PLATE and into DISK as shown in (

Figure 1)

 below using 

a 1/8" hex key/bit. Use the provided 3/16" hex key to 
lighten and secure. 

WARNING:

 It is the responsibility of the end user to ensure all aspects of installation are covered by following the full manual found at 

 http://www.amico.com/products/capsule-neuron-mounts.

NOTE:

 Tools for installation not provided by Amico Accessories. Verify the weight of the monitor to be mounted. This product is rated at 20 lbs

 TOTAL

including 5 lbs in the basket. The

 CAPSULE NEURON 2

 must be mounted with the 

NIBP PACK* 

as shown in

 (Figure 2)

. The C

APSULE NEURON 2

 can only be 

mounted to 

CS-SLVP-ADA-00

 without the 

NIBP PACK

 in a non-flush configuration. 

Installation Reference

CAPSULE NEURON 2  

(NOT PRODVIDED)

3 X

 

FLAT HEAD SCREW

[H-FHCS-1032-58]

Accessory Mounting

Accessory Basket  

with Capsule Neuron 2

CS-SLVP-ADA-00

Quick Setup to Attach Accessory Basket to Amico Mount

For use with Capsule Neuron 2 (Vitals Plus)

1.  Insert 4 x 

PAN HEAD SCREWS

 through 4 x 

LOCK WASHERS

 

through the back of the

 MOUNTING PLATE 

and into the 

device

 (CAPSULE NEURON 2 AND NIBP PACK*)

 as shown 

below. 

MOUNTING PLATE

[X-CS-NRN2-BSK-PLT]

(A PART OF CS-SLVP-ADA-00)

DISK [MON-SWIV-DISK-T]

(A PART OF AHM-_4-_  

OR SSM-_4-_)

*NIBP PACK  

(NOT PRODVIDED)

4 X

LOCK WASHER

[H-WLM-M4]

4 X

PAN HEAD SCREW

[H-PHMS-M4-14]

MOUTING PLATE  

[X-CS-NRN2-BSK-PLT]

(PART OF CS-SLVP-ADA-00)

Hex Key: 1/8"

Phillips Head Screwdrivers: #2, #3

Hex Key: 1/8"

CS-SLVP-ADA-00

Figure 2

Installation Reference

CS-SLVP-ADA-00

HARDWARE

Reviews: