background image

10

     Amico Beds Corporation

Head Section Articulation

TO LOWER THE HEAD SECTION

a.  Squeeze the bar under the head section and push down on the head section.

b.  Release the bar when the desired position is reached. The head section  

locks in place.

Knee Surface Articulation Crank

TO RAISE THE KNEE SURFACE

a.  Pull out the crank handle from its stored position under the foot 

section.

b.  Turn the crank handle clockwise until the knee surface reaches the 

desired position.

TO LOWER THE KNEE SURFACE

a.  Pull out the crank handle from its stored position under the foot 

section.

b.  Turn the crank handle counterclockwise until the knee surface reaches the desired position.

After raising or lowering the knee surface, return the crank to its stored position. 

Permanent Telescopic IV Pole

The permanent IV pole is available as an option on the Titan Transport Stretcher (S-AM1-300X).

 

WARNING: 

Do not exceed the load capacity of the IV pole. If the IV pole is overloaded, personal injury or 

equipment damage may occur. The safe working load of the pole is 30 lbs. 

Summary of Contents for S-AM1-300X

Page 1: ...Operation Maintenance Manual Titan Transport Stretcher S AM1 300X...

Page 2: ...ition 9 To Level the Sleep Surface 9 Head Section Articulation 9 To Raise the Head Section 9 To Lower the Head Section 10 Knee Surface Articulation Crank 10 To Raise the Knee Surface 10 To Lower the K...

Page 3: ...the centre of the base This manual provides instructions required for normal operation of the Titan Series Stretcher S AM1 300X from Amico Beds Corporation Prior to operation of this stretcher it is...

Page 4: ...ectric shock fire and mechanical hazards only in accordance with UL60601 1 CAN CSA C22 2 No 601 1 IEC60601 1 2 38 and IE60601 2 46 CPR control Activates the CPR function Stretcher down control Shows w...

Page 5: ...meter Stretcher Lift Capacity 550 lbs 250 kg Total Weight Without Surface 300 lbs maximum 136 kg maximum Head Section Inclination maximum 80 5 Knee Section Inclination maximum 35 5 Stretcher Height Ra...

Page 6: ...endelenburg reverse Trendelenburg control pedals 2 Mattress 8 Oxygen tank holder and patient item storage 3 Transport handles 9 Brake neutral pedal 4 IV pole mounting socket 10 Knee surface articulati...

Page 7: ...wards the up position until the latch locks in place TO LOWER A SIDERAIL Lift the latch to unlock the siderail Hold latch in up position while lowering the siderail then release Mattresses WARNING Onl...

Page 8: ...al position The steering system is optional on the Titan Series Stretcher S AM1 300X The steer function is used to keep the stretcher moving in a straight line and to make it easier to turn corners Hi...

Page 9: ...pedal to lower the stretcher to its lowest position The sleep surface levels automatically b If the stretcher is in the Trendelenburg position press the reverse Trendelenburg control pedal until the...

Page 10: ...e knee surface reaches the desired position TO LOWER THE KNEE SURFACE a Pull out the crank handle from its stored position under the foot section b Turn the crank handle counterclockwise until the kne...

Page 11: ...ket b Grasp the top section of the IV pole loosen the knob and raise it until the desired height is reached Tighten the knob to hold the IV pole in position TO LOWER THE PERMANENT IV POLE a Loosen the...

Page 12: ...the facility protocols for safe positioning When raising the siderails a click indicates that the siderails are completely raised and locked in place Once the click is heard gently pull on the siderai...

Page 13: ...d by needle sticks Caregivers should be instructed to avoid punctures caused by improper use of X Ray cassette holders and or needle sticks Failure to do so could result in cross infection and patient...

Page 14: ...Series Stretcher S AM1 300X PM will minimize downtime due to excessive wear Perform annual preventive maintenance procedures to make sure all Titan Series Stretcher S AM1 300X components are function...

Page 15: ...o clean or degrease the steel Use only approved cleaning products If bleach is being applied to the product strictly adhere to the Bleach Cleaning Instructions Do not use a water temperature of more t...

Page 16: ...ace with one of the approved cleaners or refer to the Bleach cleaning instructions if bleach needs to be used Wipe off residue with water using a soft cloth or sponge Thoroughly dry Before Cleaning Di...

Page 17: ...ng to Amico Beds Corporation specifications used in a normal manner and serviced according to factory recommendations It does not cover failures due to damage which occurs in shipments or failures whi...

Page 18: ...18 Amico Beds Corporation Notes...

Page 19: ...www amico com 19 Notes...

Page 20: ...m AB IM TITAN TRANSPORT STRETCHER 03 30 2022 Amico Beds Corporation 85 Fulton Way Richmond Hill ON L4B 2N4 Canada Toll Free Tel 1 877 462 6426 Tel 905 764 0800 Fax 905 764 0862 Email info amico com ww...

Reviews: