Industry Cellular Gateway
Interface
RS-232 is set by default
Select RS-232 or RS-485 physical interface for connecting to the access device(s)
with the same interface specification.
Baud Rate
19200 is set by default
Select the appropriate baud rate for serial device communication.
RS-232: 1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200
RS-485 can use higher baud rate for 230400 and 460800. It depends on the cable
length and the installed environment. The longer cable, the lower baud rate for it.
Data Bits
8 is set by default
Select 8 or 7 for data bits.
Stop Bits
1 is set by default
Select 1 or 2 for stop bits.
Flow Control
None is set by default
Select None / RTS, CTS / DTS, DSR for Flow Control in RS-232 mode.
The supporting of Flow Control depends on the purchased model.
Parity
None is set by default
Select None / Even / Odd for Parity bit.
Action
N/A
Click
Edit
button to change the operation mode, or modify the parameters
mentioned above for the serial interface communication.
Save
N/A
Click
Save
button to save the settings.
Undo
N/A
Click
Undo
button to cancel the settings.
182