Industry Cellular Gateway
Select
Binary mode
or
String mode
for the serial interface.
VAP
: This means the virtual AP. When WiFi and VAP are enabled,
it can be selected here.
Save
N/A
Click the
Save
button to save the configuration.
Undo
N/A
Click the
Undo
button to restore what you just configured back to the
previous setting.
Once you enabled the Packet Analyzer function on specific Interface(s), you can further specify some filter
rules to capture the packets which matched the rules.
Capture Fitters
Item
Value setting
Description
Filter
Optional setting
Check
Enable
box to activate the Capture Filter function.
Source MACs
Optional setting
Define the filter rule with
Source MACs
, which means the source MAC address of
packets.
Packets which match the rule will be captured.
Up to 10 MACs are supported, but they must be separated with “
;”
,
e.g. AA:BB:CC:DD:EE:FF; 11:22:33:44:55:66
The packets will be captured when match any one MAC in the rule.