Industry Cellular Gateway
Value Range
:
2000 ~ 3000 seconds.
Fail Threshold
1. An Optional setting
2.
10 times
is
set by
default
Enter a number of detecting disconnection times to be the threshold
before disconnection is acknowledged.
Fail Threshold
specifies the detected disconnection before the router
recognize the WAN link down status.
Value Range
:
1 ~ 10 times.
Target 1
1. An Optional filled
setting
2.
DNS1
is selected by
default
Target1
specifies the first target of sending DNS query/ICMP request.
DNS1
: set the primary DNS to be the target.
DNS2
: set the secondary DNS to be the target.
Gateway
: set the Current gateway to be the target.
Other Host
: enter an IP address to be the target.
Target 2
1. An Optional filled
setting
2.
None
is selected by
default
Target1
specifies the second target of sending DNS query/ICMP request.
None:
no second target is required.
DNS1
: set the primary DNS to be the target.
DNS2
: set the secondary DNS to be the target.
Gateway
: set the Current gateway to be the target.
Other Host
: enter an IP address to be the target.
Save
N/A
Click
Save
to save the settings.
Undo
N/A
Click
Undo
to cancel the settings.
58