©Copyright Amkus Rescue Systems, Inc. 2010 - 2020
LAS-001 June 22. 2020 Rev07
3
1.0 MEANING OF SAFETY SIGNAL WORDS
A safety related message is identified by a safety alert symbol and a signal word to indicate the level of risk involved with a particular
hazard. Per ANSI standard Z535.6, the definitions of the four signal words are as follows:
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor
or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
2.0 SPECIFICATIONS
Length
29.7 in. (754 mm)
Width
14.0 in. (356 mm)
Depth
8.0 in. (203 mm)
Weight (ready to use)
(Ready-to-use with Standard couplings)
37.35 lbs. (17.0 kg)
Maximum Spreader Opening
24.0 in. (610 mm)
Maximum Spreader Travel Distance
23.9 in. (607 mm)
Spreader Opening Time 4 seconds
Spreader Closing Time 4 seconds
Rated Input Pressure
10,500 psi (724 bar)
Highest Spreading Force HSF
10,100 lbs. (44.8 kN)
Lowest Spreading Force LSF
9,145 lbs. (40.6 kN)
Highest Pulling Force HPF
6,218 lbs. (27.6 kN)
Lowest Pulling Force LPF
5,450 lbs. (24.2 kN)
Fluid Type AMKUS MV1 Mineral Base Hydraulic Fluid
Safety Data Sheet (SDS) for AMKUS MV1 Hydraulic Fluid is available
at AMKUS.com and CHEMTREC.com
(For equipment stored and operated in environments below 32 deg. F (0 deg
C) contact Amkus Rescue Systems for recommendation.