7.0 OPERATION
7.1 BATTERY CHARGE STATUS
Check the battery charge status using the indicator lights on the battery by pushing the status button on the battery.
Figure 7.1
7.2 WHEN TO CHANGE THE BATTERY
ION tools keep power ON until turned off, or after 20 minutes of inactivity. The battery management system maintains power until the
battery is drained. Push the status button on the battery to check the battery status. The indicator light bars display the battery’s charge
status.
Change the battery if the battery no longer continuously operates the tool, there is one bar left on the battery charge indicator, or the
Status LED indicates “red” for low battery.
7.3 STORAGE RECOMMENDATIONS
1. The best storage place is cool and dry, away from direct sunlight and excess heat or cold.
2. For long storage, it is recommended to store a fully charged battery pack in a cool dry place out of the tool and charger for optimal
results.
3. If the tool is exposed to water, remove the battery. Allow the battery and tool to dry before storage or use.
7.4 CUTTING
Rotation of the control valve actuator runs the electric motor and pump. Rotating the control valve actuator regulates the hydraulic flow
rate and power delivered to the tool. Turning the control valve actuator to the end stops provides maximum hydraulic flow rate and
power.
Figure 7.4A