5.6 Main te nance work en gine – Hatz
Only the main te nance work which has to be per formed daily
is in cluded in the Op er at ing Man ual. Please re fer to the en -
gine Op er at ing Man ual and to the main te nance in struc tions
and in ter vals listed therein.
5.6.1 Fill ing-up with fuel
•
Stop the en gine.
•
Clean around the fuel filler socket.
•
Open the fuel filler socket and
•
Vi su ally check the fuel level. An un us able amount of fuel re -
mains in the tank due to the de sign.
•
Top-up if nec es sary; all die sel oils sold as fuel and com ply ing
with the fol low ing min i mum spec i fi ca tion can be used: EN 590;
DIN 51601 - DK; BS 2869 A1 / A2; ASTM D 975 - 1D / 2D.
•
Close the tank tightly.
5.6.2 Check ing Cool ing air-/com bus tion air-in take
Check in take open ing for com bus tion air and cool ing air in takes.
Re move coarse ostructions such as leaves, stones and earth.
5.6.3 Check the en gine oil level
•
Stand the ma chine hor i zon tally.
•
Stop the en gine.
•
Clean the area around the dip stick (5).
•
With draw the dip stick (5) and wipe with a clean, fi bre free
cloth.
•
To check the oil, screw the dip stick back in and then re move it
again.
•
Check the dip stick oil level and, if nec es sary, add oil to the
«
max
» mark.
5.6.4 Check the wa ter trap
Check the wa ter trap on its wa ter con tent ev ery day, when the en -
gine oil level is checked. The wa ter which has col lected is sep a -
rated at a clearly vis i ble line from the die sel fuel above it.
•
Open drain plug (3) and
•
drain the wa ter outinto a suit able ves sel.
5. Main te nance
59
Danger
Only top-up by sta tion ary en gine.
No open fire.
Do not smoke.
Do not fill-up in closed rooms.
Do not in hale fuel fumes.
Col lect spilt fuel in a suit able con tainer and pre -
vent spill age en ter ing the soil.
1B20_3.cdr
B3299021.cdr
DIESEL
1
AVP 2220 / 2620:
max. 3
l
/ 0.79 US gal
AVP 3020 / 3520:
max. 5
l
/ 1.32 US gal
1
max
B5899015.cdr
OIL
SAE 10W/40
B5399027.cdr
3
Environment
Im me di ately re place dam aged seals.
Col lect old oil and dis pose of it in an en vi ron ment
friendly man ner.
Do not per mit oil to run onto the floor into the
drains.