Data registration
Ammonit GmbH / 2005 - 2009
25
3.1.5. Data format of measurement series
Data output can be in TEXT files as ASCII code that the user can read directly
and process with most text editors. A new time code is inserted into the data
after a RESET, after a cold start or after an interruption in the measurement
operation and automatically at:
T 10/20/92 11:13:33 10*600
Identification letter
Starting time /
and date
Scan interval in [s]
Number of scan
values
Product delivers
log interval
in seconds
Using "CALLaLOG" software to transfer data converts the time code into time
and date at the beginning of each line.
The data for one log interval is displayed in one line. The numbers are
separated by BLANKS, leading zeros are suppressed and at the end of each
line there is the control character for "line end": CR. The order and the number
of columns correspond to the parameters programmed into the parameter file.
Example of a measurement delivering a wind speed:
average value (4.5 m/s), maximum value (6.2 m/s), standard deviation (1.4 m/s)
and mean wind direction 156°:
45 62 14 156