8.2. WindTracker
The Young WindTracker is a compact wind speed and wind direction display
which can be used directly with Ammonit Loggers. It includes a programmable
alarm output.
To install the WindTracker, connect the “A” and “B” pins between WindTracker
(RS-485 terminal) and Logger (RS485 port on “Supply”) and insert the power
supply plug.
Setting up the data logger
Start “CALLaLOG” and choose “RS485 Options”
(Connect / Settings / RS485 Options)
•
Enable Wind Display output
•
Select wind data channel (1 or 2) and upload new configuration.
Setting up the Windtracker
•
Press and hold ENTER and SELECT keys for about 5 seconds. The
left display will show “InP”.
•
Press SELECT until right display shows “SEr”.
•
Press ENTER repeatedly until the display returns to normal operation.
Remarks:
•
The measurement interval of the logger should not be more than 3
seconds, so as to avoid a “serial error” report on the display.
•
You can activate the “Alarm” function of the wind display. Please read
the “WindTracker” manual for further information.