How to load factory settings
If You want to/need to get back all parameters, which are provided with the
unit at delivery state ("factory settings"), proceed like this:
•
check if You need any collected data in the logger, if yes load and save
them
•
disconnect ALL supplies (batteries, external)
•
press the "Select" button, hold it down and connect one supply again
wait until You see the text "factory settings" on the display; then You can
release the "Select" button: the factory settings are loaded.
ATTENTION: As mentioned, this action clears all data within the
data logger, there is no recovery possible!
Updates
The software for the Data Loggers is constantly being developed further. In
order to allow you to benefit from the latest functions and options for your
measurement systems, it is possible to upload up-dated user software via the
serial interface, including by telephone or GSM-connections. To obtain the
necessary programming files and further information, contact
ammonit@ammonit.
com.