Technical Data
Housing:
Material
Polycarbonat
Dimensions
HxBxT [mm]: 120 x 200 x 75
Weight
approx. 1 kg
Protection type
IP 65, waterproof
Connector sockets
Miniature-round-socket connectors
screwed: protection type IP 67
Cap screw
V2A
Power Supply:
Operating batteris
2 Alkaline-Batteries, approx. 550mAh
(9V E-Block - 6LR61 - PP3)
can be replaced by Lithium batteries
External
DC 10 ... 24 Volt
Power consumption:
Standby
approx. 0,5 mA between the measurements
Meas. Operation
approx. 45 mA
Temperature range:
Meas. Operation
- 40 ... + 85 °C
Display readable
- 10 ... + 50 °C
Measurement inputs:
Anemometer
Number
3 wind speeds
Variable
Pulses
Signal level
TTL-Level
Meas. range
0 ... 2000 Hz
Resolution
0,1 m/s
Wind vane (potentiometric)
Number
2 wind directions
Variable
resistance proportion (wiper position of the
potentiometer)
Meas. range
0° ... 360°
Resolution
1°
Potentiometer
2000
Ω
... 10000
Ω
resistance