iMAC2 CONTROLLER SPECIFICATIONS
Supply Voltage (+, - & E Terminals)
Voltage
24VDC (±20%)
Power Consumption
< 15VA
Inrush Current
2.6A for 175ms
Operating Temperature
0 to +60
˚C
Storage Temperature
-20 to +80
˚C
L1 Fieldbus (L1+, L1- Terminals)
Surge Protection
90V Lightning Arrestor
Maximum Series
Resistance to EOL
800
Ω
Minimum Shunt
(Insulation) Resistance
1000
Ω
Minimum Baud Rate
300
Maximum Baud Rate
1000 (dependant on cable type/length and module quantity/type/distribution)
L2 Fieldbus (L2+, L2- Terminals)
Optically Isolated
10kV
rms
Minimum Baud Rate
300
Maximum Baud Rate
1000
Switches & Selectors
Type
Location
Function
16 Position Selector
Access via right side of enclosure
Application software (SLP) dependent
4x DIP Switches
Access via right side of enclosure
Application software (SLP) dependent
Ethernet Reset Switch
Access via left side of enclosure
Reset IP settings to defaults
General Purpose Inputs (SW1+ & SW1-, SW2+ & SW2-, SW3+ & SW3- Terminals)
Quantity
3 (Self Wetting)
Self-Wetting Voltage
12V (Nominal)
Self-Wetting Current
10mA (Nominal)
Wiring
Twisted pair, <20m (per input)
Function
Application software (SLP) dependant
Optically Isolated
1kV
Output Relay Contacts (CR, AR Terminals)
Contacts
1 x NO Control Relay (CR) Contact
1 x NO Auxiliary Relay (AR) Contact
Ratings (Resistive)
10A, 250VAC, 30VDC (min 10mA, 5VDC)