Smart 8-Stage Charging Program
1.
Battery Desulfation
- Adopt 15.8V pulse voltage for electrolytic removal
of sulfated crystals. Automatically skip when not needed.
2.
Soft Start
- A slow and steady buildup of the charging process that limits
the power input to protect your battery.
3.
Bulk Charging
- The main part of the whole charging process where the
battery power will reach about 80% full.
4.
Absorption
- Fully charge the battery by slowly reducing the charging
rate to allow your battery to absorb more power.
5.
Battery Analysis
- Auto-test the battery state after charging. Abnormal -
enter the repair stage; Normal - turn to the next stage.
6.
Battery Recondition
- Restore over-discharged batteries. After repair,
return to the "Bulk" stage. If it fails, an error will be reported.
7.
Float Charging
- Keep battery at 100% without overcharging or
damages; Leave smart charger 24/7 plugged without worry.
8.
Pulse Maintenance
- Auto-wake up and pulse compensate to 100% full
again when the voltage drops, with battery more durable.
1
2
3
4
5
6
7
8
Desulfation
Voltag
e
Curr
ent
Soft Start
Bulk Charging
Absorption
Analysis
Recondition