The above is the main display information of the main page while working, that
red LED on indicates that AMP01 spark inspection control main-board works in
normal state while Green LED on indicates that there is new alarm information. After
reading the alarm records, it returns to the original state.
b. The search of alarm record
When you push the alarm record button, you can enter the page of the latest alarm.
LCD displays the time of year, month, date, hour and minute.
Then you push
△
key, you can turn to the previous alarm history. You can
continuously turn to the front page. When “NO RECORD” is shown, it shows that
there is no record and the system will automatically return to main page.
When we push
ESC/DELETE
key , it exits to the alarm history page. If there is
no instruction in the alarm history page, it can also exit to the main page after 10
second.
▲Caution!
This computer can store 20 alarm messages. If the number exceeds 20, the
history record would be automatically cleared and displays"
♬
01". That is to say,
it can only store the 21
st
message, the original 20 messages would be
automatically cleared.
c. Operation in case of alarm
In case of the alarm, the instrument sends the sound and light alarm signals and
shuts down automatically, at the time, the displaying clock in LCD main page stops.
After pushing
RESET ALARM
key, the alarm status will be eliminated and the
instrument returns to the normal working status. The main page of LCD returns to the
normal time (During the alarm, though the displaying clock stops, the inner is still
timing, so it would automatically enter to the correct time after elimination of the
alarm.) and the message number of alarm will be increased by one.
d. The deletion of alarm record
On the main displaying page of LCD, when you push
ESC/DELETE
key, the
latest alarm record will be deleted. The function is mainly used in the fire alarm
inspection by maintenance personnel for deleting automatic alarm record while doing
inspection test.
e. Time setting
The time has been set when delivered, in the ordinary course of event, it is not