AMPEON AMP-Series
http://www.ampeon.cn
21
the diverter acts, that indicates that the metal detection function of this equipment is
normal.
e. If the diverter has taken the actions, but you can’t find the test metal in the
collect box, you should carefully observe and repeatedly adjust closing delay
parameter until you can reliably discharge the test metal. In the meantime, you should
assure the dropped volume is the minimum. After repeat test, if you still can’t divert
properly, it is necessary to reconsider the install distance from metal detector to
diverter.
▲Caution!
a) The dropped cotton batting in the collect box of diverter needs to be cleaned
immediately, or it will damage the diverter.
b) We also need to carry out regular simulation test and check to the metal
diverter and trash separator to assure the good working state.
D.RS-232 communication
1. Function of RS-232 communication connector
RS-232 communication connector is installed in AMP-2000V5 metal & spark
diverter (Figure 16). RS-232 communication connector is specially designed for
user’s computer management and various distance communications. It can adapt to
the situation that workshop network management requires the end terminal computer
displays the working status of the diverter and the parameters is revised online.
Jiangsu Ampeon Electron Engineering Co., Ltd. provides open network
communication protocol.
Figure 16: RS-232 communication connector