Setting Up ( Con’t )
Up to 16 units can be cascaded, if number of schedules in a unit is insufficient or number of channels are more than
8. This setting is only applicable if RS485 data is communication is used, or linked to a PC for monitoring.
5.0 CASCADE
5.0 CASCADE
- Use NEXT/PREV button to determine the unit’s cascading address
- Press ENTER to confirm the address number
- The menu shall return to 5.0.
Enter
5.1 Cascade No.
01
6.0 FACTORY RESET
This is to delete all the settings done previously and return to factory default settings.
6.0 FACTORY
RESET
- Use NEXT/PREV button to select YES or NO
- Press ENTER to confirm selection
- The menu shall return to 6.0 above.
Enter
6.1 Fact. Reset
NO ?
7.0 SYSTEM
System update and bootloading, enter this menu.
7.0 SYSTEM
- Use NEXT/PREV button to select YES or NO
- Press ENTER to confirm selection
- The menu shall return to 7.0 above
Enter
7.1 FIRMWARE
VER: v02.05
8.0 EXIT
To exit programming mode, enter this menu.
8.0 EXIT
- Use NEXT/PREV button to select YES or NO
- Press ENTER to confirm selection
- If NO, the menu shall return to 1.0 otherwise to time display ( running mode ).
Enter
8.1 Exit
NO ?
Enter
7.2 UPDATE
YES ?
PAGE 10
PT1801 | MULTICHANNEL PROGRAMMABLE TIMER
- Please refer to section “ Firmware Upgrading” to enter this function.