background image

QUICK START

1.  Fit CLD1-AC to a panel or wall under the counter, away from contact by the 

system user. Ensure the cables are positioned such that they are not vulnerable 
to damage and are unlikely to be snagged or disconnected from the unit.

2. Fit either the loop coil (provided) or perimeter loop:

·

 

Unfold the loop coil and fit vertically inside the front panel of the counter 

using the adhesive fixings provided. The top of the loop coil should ideally 
be at a height of 800mm above the floor.

Glass screen

   (if fitted)

Place coil

immediately

below counter

Obstruction

Figure 2

Glass screen

   (if fitted)

Counter

or

Desk

(customer side)

Counter

or

Desk

(customer side)

Place coil

immediately

below counter

Figure 1

Do not position

coil in this

position

·

 

If a perimeter loop is to be used, the feed wires to the amplifier should 

be twisted together. See 'Designing Induction Loops handbook' for details.

3. Connect the loop wires to 'LOOP OUTPUT' terminals. Polarity is not important. 

To open the spring clamp terminal - insert a flat bladed screwdriver into the 
small “tab” above the hole. Push gently until hole opens.

4. Connect signal to 'INPUTS 1 and 2' as required 

(see: 

Connection details

)

.

5. Position 'INPUT 2 SELECT' slide switch for Line or Mic as required.

6. Connect AC power cable to 'POWER INPUT' socket on the unit. Connect  to AC 

supply.

7. Switch on external AC power: Check green 'POWER' LED illuminates.

8.  Apply input signal (e.g. by speaking into mic') and if required increase 

corresponding  'INPUT 1 or 2' control until the green 'INPUT SIGNAL' LED 
begins to light.

9. Repeat item 9 for the second input (if used). 

Only apply one audio signal at a 

time when setting up the system.

10. If required adjust the 'LOOP CURRENT' control until the yellow 'LOOP 

CURRENT' LED lights at peaks in the input signal.

11. Test the performance of the system using a loop receiver or field strength 

meter and adjust 'MLC' & 'LOOP CURRENT' to achieve acceptable 
performance.

     Note: Once the 'LOOP CURRENT' control is set, do not adjust it again.

Summary of Contents for CLD1-AC

Page 1: ...ct ventilation of this unit Install in accordance with the manufacturer s instructions 5 Do not install near any heat sources such as radiators heating vents or other apparatus that produces heat 6 Re...

Page 2: ...de j Microphone input for use with unbalanced electret microphones k Selectable microphone or unbalanced line level input Mic mode as above l AC power input standard 2 pin AC power socket m Loop outpu...

Page 3: ...Connect the loop wires to LOOP OUTPUT terminals Polarity is not important To open the spring clamp terminal insert a flat bladed screwdriver into the small tab above the hole Push gently until hole o...

Page 4: ...LOCK DIAGRAM Balanced Input A B Screen Connect screen and ve signal lead together Stereo Source Left Right Screen Keep all wires very short 10k 10k L R Screen Ideally fit the two 10k W summing resisto...

Page 5: ...area a perimeter loop using 0 5mm to 1 5mm cross section wire or equivalent Return the feed to the amplifier with a twisted pair Refer to Designing Induction Loops handbook for details Please consult...

Page 6: ...iate see OPERATION Input signal level too low Check that signal level is the correct level for the chosen input see TECHNICAL SPECIFICATIONS LOOP CURRENT LED not illuminated even at peaks of signal Lo...

Page 7: ...e selectable with switch Fully anticlockwise flat response Mic mode same as Input 1 Environmental Line mode Ambient temperature 20 C to 50 C Input Impedance 820kW IP rating IP20 Sensitivity 20dBu 77 5...

Page 8: ...he product Description Induction Loop Driver Type name CLD1 AC conforms to the following directive s and Norm s 2014 35 EU The Low Voltage Directive LVD and its amending directives 2014 30 EU The Elec...

Reviews: