11
RESISTANCE
Ranges: 400
Ω
, 4k
Ω
, 40k
Ω
, 400k
Ω
, 4M
Ω
,
40M
Ω
Resolution: 100 m
Ω
Accuracy: ±(1.0 % rdg + 4 dgts) on
400
Ω
to 4M
Ω
ranges
±(2.0 % rdg + 5 dgts) on 40M
Ω
range
Open circuit volts: -0.45 V dc typical,
(-1.2 V dc on 400
Ω
range)
Overload protection: 1000 V dc or
750 V ac rms
CAPACITANCE
Ranges: 4µF, 40µF, 400µF, 4000µF
Resolution: 1 nF
Accuracy:
±(5.0 % rdg + 10 dgts) on 4µF range
±(5.0 % rdg + 5 dgts) on 40µF to
400µF ranges
±(5.0 % rdg + 15 dgts) on 4000µF range
Test voltange: < 3.0 V
Test Frequency: 25Hz
Input protection: 0.315A/1000V fast blow
ceramic fuse 6.3×32mm on µA/mA input
TEMPERATURE
Ranges: -20 °C to 1000 °C, -4 °F to 1832 °F
Resolution: 1 °C, 1 °F
Accuracy:
±(2.0 % rdg + 4 °C) -20 °C to 10 °C
±(1.0 % rdg + 3 °C) 10 °C to 200 °C
±(3.0 % rdg + 2 °C) 200 °C to 1000 °C
±(2.0 % rdg + 8 °F) -4 °F to 50 °F
±(1.0 % rdg + 6 °F) 50 °F to 400 °F
±(3.0 % rdg + 4 °F) 400 °F to 1832 °F
Overload protection: 1000 V dc or
750 V ac rms
FREQUENCY
Ranges: 4k, 40k, 400k, 4M, 40MHz
Resolution: 1 Hz
Accuracy: ±(0.1 % rdg + 3 dgts)
Sensitivity:
10 Hz to 4 MHz: >1.5 V ac rms;
4 MHz to 40 MHz: >2 V ac rms, <5 V ac rms
Minimum pulse width: > 25 ns
Duty cycle limits: > 30 % and < 70 %
Overload protection: 1000 V dc or
750 V ac rms
DUTY CYCLE
Ranges: 0 to 90 %
Resolution: 0.1 %
Pulse widh: >10 µs
Frequency range: 40 Hz to 20 kHz
Accuracy: (5V logic ) ±(2.0% rdg + 5 dgts)
Overload protection: 1000 V dc or
750 V ac rms
CONTINUITY
Audible indication: < 35
Ω
Response time: 100 ms
Overload protection:1000 V dc or
750 V ac rms
DIODE TEST
Test current: approximately 1.2 mA
Accuracy: ±(1.5 % rdg + 3 dgts)
Resolution: 1 mV
Open circuit volts:
3.0 V dc typical
Overload protection: 1000 V dc or
750 V ac rms
ADDITIONAL FEATURES
µA
mA
, 10A Test Lead Connection:
Beeps
to warn test leads are connected to
measure current while Function/Range
Switch is not set to a measure current.
MIN MAX:
Displays the minimum or
maximum value detected while making a
measurement.
HOLD:
Holds the latest reading on the
display.
RANGE:
Manual range mode.
Backlight:
Backlight auto-off
approximately 60 seconds
Auto Power off:
30 minutes, typical
REPLACEMENT PARTS
TL36 Test Lead Set with Alligator clips
FP300 mA fuse - Fuse Pack .315A/1000V
(4 each)
FP100 10A fuse - Fuse Pack 10A/1000V
(2 each)
XR-TA Input Adapter for K-type
thermocouple
TP255 K type thermocouple
XR-H2 Magne-Grip
®
Holster, clip, magnet,
and strap
Summary of Contents for 30XR-A
Page 3: ...C M Y CM MY CY CMY K pn2728939_cover_press pdf 8 23 2006 3 45 55 PM ...
Page 4: ... MADE IN TAIWAN PATENTS PENDING www amprobe com 5 6 3 4 1 2 34XR A 34XR A ...
Page 6: ......
Page 18: ...12 4 3 2 1 5 4 3 2 1 5 1 2 V V 34XR A 34XR A ...
Page 20: ...14 2 1 8 3 4 5 4 7 5 6 4 7 5 6 A 3 A 2 1 8 34XR A 34XR A ...
Page 21: ...15 3 4 6 5 2 1 5 3 4 6 6 7 2 1 7 34XR A 34XR A ...
Page 22: ...16 6 2 8 1 3 5 4 1 7 4 5 6 2 9 3 34XR A 34XR A ...
Page 23: ...17 4 11 1 3 2 2 4 K 3 1 5 10 34XR A 34XR A ...
Page 24: ...18 3 2 1 4 12 2 4 2 13 34XR A ...
Page 36: ...12 ...
Page 48: ...12 ...
Page 60: ...12 ...
Page 72: ...12 ...
Page 73: ...C M Y CM MY CY CMY K pn2728939_cover_press pdf 8 23 2006 3 45 55 PM ...