2
WARNING
To reduce the risk of fire or electric shock, do not expose this product to rain or
moisture. To avoid electrical shock hazard, observe the proper safety precautions
when working with voltages above 60 VDC or 30 VAC rms. These voltage levels pose
a potential shock hazard to the user. Do not touch test lead tips or the circuit being
tested while power is applied to the circuit being measured. Keep your fingers behind
the finger guards of the test leads during measurement. Inspect test leads, connectors,
and probes for damaged insulation or exposed metal before using the instrument. If
any defects are found, replace them immediately. Do not measure any current that
exceeds the current rating of the protection fuse. Do not attempt a current
measurement to any circuit where the open circuit voltage is above the protection fuse
voltage rating. Suspected open circuit voltage should be checked with voltage
functions. Never attempt a voltage measurement with the test lead inserted into the
µ
A/mA or A input jack. Only replace the blown fuse with the proper rating as specified
in this manual.
CAUTION
Disconnect the test leads from the test points before changing functions. Always set
the instrument to the highest range and work downward for an unknown value when
using manual ranging mode.
INTERNATIONAL ELECTRICAL SYMBOLS
!
Caution ! Refer to the explanation in this Manual
Caution ! Risk of electric shock
Earth
(Ground)
Double Insulation or Reinforced insulation
Fuse
AC--Alternating
Current
DC--Direct
Current
2) CENELEC DIRECTIVES
The instruments conform to CENELEC Low-voltage directive 73/23/EEC and
Electromagnetic compatibility directive 89/336/EEC