background image

Limited Warranty and Limitation of Liability

Your Amprobe product will be free from defects in material and workmanship for one year from 
the date of purchase unless local laws require otherwise. This warranty does not cover fuses, 
disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or 
abnormal conditions of operation or handling. Resellers are not authorized to extend any other 
warranty on the behalf of Amprobe. To obtain service during the warranty period, return the 
product with proof of purchase to an authorized Amprobe Service Center or to an Amprobe 
dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. 
ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STATUTORY - INCLUDING IMPLIED 
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY 
DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL 
OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since 
some states or countries do not allow the exclusion or limitation of an implied warranty or of 
incidental or consequential damages, this limitation of liability may not apply to you.

Repair

All Amprobe returned for warranty or non-warranty repair or for calibration should be 
accompanied by the following: your name, company’s name, address, telephone number, and 
proof of purchase. Additionally, please include a brief description of the problem or the service 
requested and include the test leads with the meter. Non-warranty repair or replacement 
charges should be remitted in the form of a check, a money order, credit card with expiration 
date, or a purchase order made payable to Amprobe.

In-warranty Repairs and Replacement – All Countries

Please read the warranty statement and check your battery before requesting repair. During 
the warranty period, any defective test tool can be returned to your Amprobe distributor for 
an exchange for the same or like product. Please check the “Where to Buy” section on www.
Amprobe.com for a list of distributors near you. Additionally, in the United States and Canada, 
in-warranty repair and replacement units can also be sent to an Amprobe Service Center (see 
address below).

Non-warranty Repairs and Replacement – United States and Canada

Non-warranty repairs in the United States and Canada should be sent to an Amprobe Service 
Center. Call Amprobe or inquire at your point of purchase for current repair and replacement rates.

USA:  

Canada:

Amprobe Amprobe
Everett, WA 98203  

Mississauga, ON L4Z 1X9

Tel: 877-AMPROBE (267-7623)  

Tel: 905-890-7600

Non-warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe distributor for a nominal 
charge. Please check the “Where to Buy” section on www.Amprobe.eu for a list of 
distributors near you.

Amprobe Europe*
Beha-Amprobe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
www.Amprobe.eu
*

(Correspondence only – no repair or replacement available from this address. European customers please 

contact your distributor.)

Summary of Contents for AMP-210

Page 1: ...210 AMP 210 EUR 600A AC TRMS Clamp Multimeter AMP 220 AMP 220 EUR 600A AC DC TRMS Clamp Multimeter AMP 310 AMP 310 EUR 600A AC TRMS Clamp Multimeter AMP 320 AMP 320 EUR 600A AC DC TRMS Clamp Multimet...

Page 2: ......

Page 3: ...P 220 AMP 220 EUR 600A AC DC TRMS Clamp Multimeter AMP 310 AMP 310 EUR 600A AC TRMS Clamp Multimeter AMP 320 AMP 320 EUR 600A AC DC TRMS Clamp Multimeter User Manual 7 2014 6003318 A 2014 Amprobe Test...

Page 4: ...ption of the problem or the service requested and include the test leads with the meter Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card w...

Page 5: ...ltage 7 Voltage detection NCV 8 Measuring AC and DC Current 9 Precise Low Current Measurement 10 Microamps A Measurement 11 Measuring Resistance Continuity and Diode 12 Measuring Capacitance and Tempe...

Page 6: ...ion AMP 210 AMP 210 EUR Series TRMS Clamp Multimeters AMP 320 TRMS CAT III 600V COM OFF NCV EF SELECT HOLD REC ZERO PEAK RMS MAX 600A 600V CAT III 1 7 8 9 2 1 1 1 4 3 5 6 11 12 10 8 Precise Low Curren...

Page 7: ...e equipment is protected by double insulation or reinforced insulation J Earth Ground CAT III Overvoltage Category lll is for equipment intended to form part of a building wiring installation Such equ...

Page 8: ...ing Read Before Using To avoid possible electric shock or personal injury Use the Meter only as specified in this manual or the protection provided by the Meter might be impaired Avoid working alone s...

Page 9: ...on test lead Disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity or diodes Use only 1 5V AAA batteries properly installed in the Meter case to power...

Page 10: ...en making current measurements disconnect the test leads from the Meter Keep fingers behind Tactile Barrier Use the proper function and range for measurements Disconnect circuit power and discharge al...

Page 11: ...econd to exit MAX MIN AVG reading memory mode Press REC PEAK RMS button one second to enter PEAK RMS mode is displayed to capture inrush current or voltage RMS values 80 ms Press a second time one sec...

Page 12: ...to NCV EF EF is displayed For AMP 310 and AMP 320 turn the rotary function switch to or press SELECT button to toggle to NCV EF mode EF is displayed 2 The voltage detection antenna is located along th...

Page 13: ...e temperatures To measure AC or DC current 1 Turn the rotary function switch to or 2 Press SELECT button to choose measurement function AC A DC A DC AC A or Hz The display reflects the chosen function...

Page 14: ...ulating currents may cause the magnetic circuits of the Jaws reach hazardous excessive temperatures To measure AC or DC low current for small conductors 1 Turn the rotary function switch to or 2 Press...

Page 15: ...locate the wire between the gas burner controller and the flame sensor 2 Disconnect one of the flame sensor wires 3 Turn the rotary switch on the Meter to 4 Connect the black test lead to the COM ter...

Page 16: ...be tested Resistance measurement The resistance reading appears on the display If the circuit is open or resistance exceeds the Meter s range the display reads OL Continuity measurement If the circuit...

Page 17: ...inal 3 Turn the Meter s rotary switch to capacitance 4 Connect the probes across the capacitor to be tested When measuring be sure to note the correct polarity of the capacitor Temperature The Meter m...

Page 18: ...connection will lead to detection failure and false indication To verify signal connection and the correct rotation indication swap any of two signal connections l to check for indication of reverse m...

Page 19: ...ws Enbp When making rotary measurement if the rotary indication segments indicate a clockwise movement the beeper sounds a single long beep per segment cycle If the rotary indication segments indicate...

Page 20: ...ections Current Hz functions via jaws 600 A ac dc rms at 400Hz Voltage 3 Phase Rotation functions via terminals 660 V dc 920 V ac rms Other functions via terminals 600 V ac dc rms E M C Meets EN61326...

Page 21: ...Crest Factor 2 5 1 at full scale 5 1 at half scale or otherwise specified and with frequency spectrum not exceeding the specified frequency bandwidth for non sinusoidal waveforms DC Voltage Range Accu...

Page 22: ...5 mV A Temperature AMP 310 and AMP 320 only Range Accuracy 40 0 C to 10 0 C 1 1 5 C 10 C to 99 9 C 1 0 8 C 100 C to 400 C 1 1 C 40 0 F to 14 0 F 1 3 0 F 14 0 F to 99 9 F 1 1 5 F 100 F to 752 F 1 2 F...

Page 23: ...5 600 0 A 1 8 5 LSD 50 Hz to 100 Hz 60 00 A 4 5 600 0 A 2 0 5 LSD 100 Hz to 400 Hz 1 Induced error from adjacent current carrying conductor 0 01 A A 2 AMP 220 and AMP 320 maximum crest factor 2 1 at f...

Page 24: ...z 60 A 600 A 40 A 50 00 Hz to 400 0 Hz Accuracy 1 0 5 LSD 1 DC bias if any not more than 50 of Sine rms 3 Phase Rotation measurement Voltage Range 65 V to 600 V sine wave only Frequency Range 35 Hz to...

Page 25: ...y with a soft cloth and allow to dry completely before using Do not use aromatic hydrocarbons gasoline or chlorinated solvents for cleaning BATTERY REPLACEMENT When battery voltage drops below the val...

Page 26: ...nfo amprobe com Everett WA 98203 Tel 877 AMPROBE 267 7623 Amprobe Europe Beha Amprobe In den Engematten 14 79286 Glottertal Germany Tel 49 0 7684 8009 0 Visit www Amprobe com for Catalog Application n...

Reviews: