Figure E-4. LED Display Pin Functions
E-8. Relay Board General Operation
(Not for NSN 6625-01-460-1499NM meters)
For products such as the ruggedized water-proof
version AMPTEC 620A-4R Igniter Tester and
remote controlled versions via the RS232C
Interface option, the internal 620A-4(R) PCB
labeled “620-relay board” replaces the range
switch S1 on the main board. IC-1 is a ribbon
cable header that goes to the top panel and
connects to the range push buttons (covered by
silicone rubber boots) and their corresponding
panel mount LEDS. IC-2 is a latch that will
latch its output to the corresponding range push
button input. Its output turns on the front panel
LED (acts as a range mode indicator LED) and
a corresponding relay that connects to the main
PCB to select the range. RL1 is for the 20-Ohm
range, RL2 is for the 200-Ohm range, RL3 is
for the 2K Ohm range, and RL4 is for the 20K
Ohm range.