3.h Monitoring
The standard stereo monitoring system is used when there are no Film paths in the
current Desk Setup. The monitoring system provides control for 4 pairs of control
room loudspeakers, a pair of studio loudspeakers and a headphone output.
The stereo monitoring system uses a set of special System Paths called SELs and
LISTENs. There can be up to 6 SELs and up to 2 LISTENs. The path names for the
SELs are SEL1 through SEL6. The path names for the LISTENs are LS1 and LS2
(this should not be confused with the two sets of small loudspeakers, L/S1 and L/S2).
The Monitoring Schematic shows how the SEL and LISTEN paths are used.
Bus and Tape
Bus/Tape switching only applies to the Tracks and controls the input signal to the
path. This is shown on the Track Signal Path Schematic.