L0126J
28
3.
DISPLAY CLOCK
– The factory default is “
Y”.
The
current time will appear on the display beneath the
scrolling message when the vendor is not in use.
4.
12/24 FORMAT
– The user can choose to display
the time in 12-hour or 24-hour (military) format. The
factory default is 12-hour format.
FREE VEND
The factory default is “
N
” for no. The vendor can be quickly set to
vend all products for free. Prices are ignored while FREE VEND
is enabled. The original prices will be restored when FREE VEND
is turned off.
Note that Free Vend will not time out on its own.
VIEW / EDIT
– The current setting is displayed, and the user can
change the setting. A warning will be briefly displayed if FREE
VEND is turned on.
AUXILIARY OUTPUT
The auxiliary output is a 5VDC signal lasting 100 milliseconds
following a successful vend. This signal can be used to trigger
user-supplied external devices. AMS does not currently supply
such accessory devices and cannot offer technical assistance for
such devices. This feature is provided only as a convenience to
those users of advanced technical skill who wish to connect such
a device to their AMS vendor and have sufficient electronic
expertise to do so.
VIEW / EDIT
– The current setting is displayed, and the user can
change the setting. Enabling the auxiliary output will not harm the
vendor or affect the performance of the vendor in any way.
DATA LOGS
The user can review recorded data on vendor temperature,
power outages, and door openings. This data is sometimes
helpful in diagnosing problems with the vendor. These logs are
cleared whenever the software is changed, and once the
maximum number of entries is reached, the oldest entry will drop
from the list. There are some special situations on these logs –
please read the Notes indicated.
1.
TEMPERATURE –
The temperature log contains
temperature measurements taken at half-hour
intervals over the previous two days. The display
shows the recording number, the recorded
temperature, and the time and date of the
recording. The log holds 96 measurements, with
number 1 being the most recent.
2.
POWER
– The power log records power failure
information. The display shows whether power went
ON or OFF, the temperature in the cabinet, and the
time and date of the recording. The log holds 10
recordings, with number 1 being the most recent.
3.
DOOR SWITCH
– The door switch log records door
openings and closings. The display shows whether
the door was OPENED or CLOSED, the
temperature in the cabinet, and the time and date of
the recording. The log holds 10 recordings, with
number 1 being the most recent.
EnergySENSIT
This feature is not used because the vendor is not equipped with
a refrigeration unit.
6 SERVICE PROGRAMMING
Summary of Contents for 28 Slim Gem
Page 2: ...L0126J ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 6: ...L0126J iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...L0126J 3 Figure 1 2 Model 28 Cabinet Dimensions For reference only 1 INTRODUCTION ...
Page 10: ...L0126J 4 Figure 1 2 Model 39 Cabinet Dimensions For reference only 1 INTRODUCTION ...
Page 12: ...L0126J 6 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 18: ...L0126J 12 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...L0126J 32 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 42: ...L0126J 36 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 43: ...L0126J 37 9 WIRING DIAGRAM ...
Page 44: ...L0126J 38 9 WIRING DIAGRAM ...
Page 48: ...L0126J 42 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...L0126J 44 THIS PAGE INTENTIONALLY LEFT BLANK ...