11
o
Clean magnetic drain plug.
o
Replace drain plug and refill to proper level using a high grade petroleum
base, rust and oxidation inhibited gear oil as specified in reducer manual.
o
Drain oil from spur gear oil bath and refill with new 85W 140 oil.
CAUTION:
Too much oil will cause over heating, and too little oil will result in gear
failure. Check oil level monthly. Also, under extreme operating conditions,
such as rapid rise or fall of temperatures, dust, dirt, chemical particles,
chemical fumes, or oil temperatures above 200 degrees F., the oil should be
changed every one to three months depending on the severity of conditions.
LUBE SCHEDULE
ITEM
LUBE FREQUENCY
TYPE LUBE
Reducer
Check Weekly
Drain and Refill
Yearly ( 2000 Hrs)
See Attached
reducer manual
Main Bearings
Every 8 Hours
Multipurpose Grease
7-10 Pumps Per
Bearing
Spur Gear Oil Bath
Check Weekly
Drain and Refill
Yearly (2000 Hrs.)
85W 140 Gear Oil