L0190D
13
4
VENDOR
PREPARATION
AND
INSTALLATION
Setting up a vendor has been divided into three stages:
CONFIRMING POWER AT OUTLET (
below), confirms
power and site suitability.
VENDOR PREPARATION
on pages 13 & 14, includes
preparations accomplished in the shop.
ON-SITE INSTALLATION
on page 15, is accomplished
on-site, where the vendor is to be located.
NOTE: These vendors are not to be installed within
motor fuel dispensing facilities.
CONFIRMING POWER AT OUTLET
Checking the Outlet (U.S. and Canada)
AMS recommends using a dedicated outlet which can supply 7
or more amps per vendor.
Using a volt meter set to AC VOLTS, check the voltage between
the positive (smaller) lug entry and the ground lug entry (or
center screw on two-lug outlets). The reading should be
between 110 volts and 130 volts
. Next, check the voltage
between the neutral (larger) lug entry and the ground. The
reading should be
0 volts
. If your results vary, contact a
qualified electrician to correct the outlet wiring before plugging in
the vendor.
Abnormal voltage, reversed polarity or improper
grounding may cause the vendor to malfunction or create
hazardous conditions in the vendor, resulting in possible
injury, damage to the vendor, or fire.
The power cord is shipped in the hopper on the inside of the
door. The cord is supplied with a standard NEMA 3-wire plug. If
there are no 3-wire outlets available for powering the vendor, a
grounding adapter may be used to convert a 2-wire outlet to
accept the 3-wire plug.
The adapter must have a ground tab
or wire which must be fastened to the center screw of the
outlet
.
If the outlet isn’t grounded, the machine could
present a shock hazard.
Checking the Outlet (Outside the U.S. and Canada)
Consult a qualified electrician to check the outlet for proper
polarity, voltage, and grounding. Check the serial plate on the
side of the door to confirm the vendor is rated for the outlet
voltage.
Electrical Service Requirement for CE Compliance
The following requirement applies only to models using ½ HP
compressors and displaying the CE mark on the serial plate. If
this requirement applies to your vendor, you will find a similarly
worded decal on the back of the vendor near the power cord.
NOTE: This requirement does not apply to any
vendor using 115V service.
ELECTRICAL SERVICE REQUIREMENT FOR CE
COMPLIANCE:
THIS EQUIPMENT IS INTENDED FOR USE ONLY IN
PREMISES HAVING A SERVICE CURRENT CAPACITY OF
AT LEAST 100A PER PHASE, SUPPLIED FROM A
DISTRIBUTION NETWORK HAVING A NOMINAL VOLTAGE
OF 400/230V. THE USER SHOULD DETERMINE IN
CONSULTATION WITH THE SUPPLY AUTHORITY, IF
NECESSARY, THAT THE SERVICE CURRENT CAPACITY AT
THE INTERFACE POINT IS SUFFICIENT FOR THIS
EQUIPMENT.
Requerimiento de Servicio Eléctrico para Certificación CE
El siguiente requerimiento se aplica solamente a los modelo
utilicen compresores de ½ HP y que muestren la marca CE en
la placa de serie. Si este requerimiento se aplica a su
dispensadora, verá una calcomanía con una terminología
parecida en la parte posterior de la dispensadora, cerca del
cordón de corriente.
Este requerimiento no se aplica a dispensadoras que utilizan un
servicio de 115V.
REQUERIMIENTO DE SERVICIO ELECTRICO PARA
CERTIFICACION CE:
ESTE EQUIPO SE PUEDE UTILIZAR SOLAMENTE EN
ESTABLECIMIENTOS QUE CONTENGAN UNA CAPACIDAD
DE CORRIENTE DE SERVICIO DE POR LO MENOS 100A
POR FASE, Y SUMINISTRADOS POR UNA RED DE
DISTRIBUCION QUE CONTENGA UN VOLTAJE NOMINAL
DE 400/230V. EL USUARIO DEBERA CONSULTAR CON UNA
AUTORIDAD DE SUMINISTRO, SI ES NECESARIO, PARA
VERIFICAR QUE LA CAPACIDAD DE CORRIENTE DE
SERVICIO EN EL PUNTO DE INTERFASE ES SUFICIENTE
PARA ESTE EQUIPO.
Les Utilites Electriques Necessaire Pour Conformement Aux
Regles CE
Le suivant condition applique seulement à modèle en utilisant ½
HP compresseur et montrer le CE sur l'en série plaque. Si cette
condition s'applique à votre vendeur, vous verrez un decal de
même exprimé sur le dos du vendeur près du cordon
d'alimentation.
Cette condition ne s'applique pas au service de 115V d'utilisation
de vendeur.
LES UTILITES ELECTRIQUES NECESSAIRE POUR
CONFORMEMENT
AUX REGLES CE:
CET EQUIPEMENT NE DOIT UTILISER QUE SUR LES LIEUX
AVEC UNE CAPACITE DU COURANT AU MOINS 100A LA
PHASE, FOURNIE A UN RESEAU DE DISTRIBUTION AVEC
UN VOLTAGE NOMINAL DE 400/230V. LA PERSONNE QUI
SE DETERMINER PENDANT UNE CONSULTATION AVEC
L’ADMINISTRATION DU SECTEUR, S’IL FAUT, QUE LA
CAPACITE DE COURANT AU POINT D’INTERFACE EST
ASSEZ POUR CET EQUIPEMENT.
NEVER USE AN EXTENSION CORD
WITH THE VENDOR.
Summary of Contents for EPIC SENSIT 3
Page 12: ...L0190D 6 THIS PAGE INTENTIONALY LEFT BLANK ...
Page 18: ...L0190D 12 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 26: ...L0190D 20 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 44: ...L0190D 38 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 46: ...L0190D 40 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...L0190D 44 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 52: ...L0190D 46 THIS PAGE INTENTIONALLY LEFT BLANK ...