L0192A
30
OUT OF SERVICE MESSAGE
Critical errors will disable the vendor. When this happens, an
“OUT OF SERVICE” message will be generated and when the
Control Box cover is opened the Display will show “CHECK
MESSAGES IN SERVICE MODE”. In the Touchless vendor,
the only possible source would be an inoperable Insight device,
Interceptor device or stuck keypad switch.
To get the vendor back in service, press the mode switch on the
control board. Any errors will be displayed immediately. Refer to
the list of error codes and explanations below.
Correct the cause
of the error first,
then press “
0
” to clear the error code. Certain
errors will have more detail available: press
1
to see more
detailed (sublevel) error codes, or
2
for date/time of last
occurrence.
ERROR CODES: CAUSES AND SOLUTIONS
Viewing Top Level Error Codes
To view top level error codes, enter the service mode by
pressing the mode switch located at the lower right corner of the
control board.
ACCOUNTING DATA
will be displayed if there
are no errors or an error has been cleared (whether corrected or
not). If the error message has been cleared, but the cause has
not been corrected, the message can be re-displayed by briefly
turning off the power. Use the keypad buttons to perform the
following:
# - NEXT ERROR
– to view the next top level error
code in memory.
2 - DETAILS
– displays the time and date of last error
occurrence.
1 - SUBLVL ERRORS
– to display any sublevel error
codes including MDB devices.
0 - CLEAR ERROR
– to erase the error code from
memory (first correct the error).
Viewing Sub-Level Error Codes
To view the sub-level error codes, press the 1 key while the top
level error code is being displayed.
Correct the condition which
caused the error first, then clear the error code by pressing “0”.
Once all errors are cleared,
ACCOUNTING DATA
will be
displayed.
CLEARING JAMMED MOTOR
If one or more vend motors and helices become jammed, the
motor ID(s) will be displayed as a sublevel error under “Motor
Jammed”.
Energized vend motors can turn a helix with considerable
torque, creating a possible entrapment hazard. Disconnect
power to the vendor or control board before freeing a
jammed helix or motor.
Always restrain or block the helix
before freeing a jammed or caught product.
CAUTION
:
Use caution when freeing jammed product
Clear any jammed products from the indicated selections.
To reset the error, first enter service mode, then select Tray
Setup (See
TRAY SETUP
on page 22). Press “
1
”, then “
*
”, then
“
3
”. The control will attempt to run the jammed motors. If the
motor had been taken out of the motor matrix, it will be
re-established in the matrix.
7
TROUBLESHOOTING
ERROR CODES – CAUSES AND SOLUTIONS continued
TOP LEVEL
ERROR CODE
SUB LEVEL
CODE
CAUSES
SOLUTIONS
CARD READER
A message has been generated by the Insight device. Press
1
to see sub-level error codes.
COMM
There are no
other messages
generated by the
Vagabond Insight
Device
Communications error.
If you see any other messages, either
the AMS Control Board had been in
another machine and this error was
created there, or there is a problem
with the AMS Control Board.
Check MDB harness connections.
If you clear the error and it returns, change the AMS
Control Board.
Summary of Contents for TOUCHLESS
Page 9: ...L0192A 3 Figure 1 2 Cabinet Dimensions 1 INTRODUCTION ...
Page 12: ...L0192A 6 THIS PAGE INTENTIONALY LEFT BLANK ...
Page 18: ...L0192A 12 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 22: ...L0192A 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 26: ...L0192A 20 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...L0192A 28 6 SERVICE PROGRAMMING THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...L0192A 32 MACHINE TROUBLESHOOTING CHART CONTINUED THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 42: ...L0192A 36 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 43: ...L0192A 37 9 WIRING DIAGRAM ...
Page 44: ...L0192A 38 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 49: ...L0192A 43 ...
Page 50: ...L0192A 44 THIS PAGE INTENTIONALLY LEFT BLANK ...