American Security Products Co
Part #4305278
AMSEC Biometric Safe Lock Operating Instructions
02/10
7
3. Enroll additional fingerprint and its bound code (Level 2)
Place an enrolled administrator’s finger (ID No. 01 or 02) on the reader window and hold.
After the fingerprint and its bound code are verified successfully, the LCD screen shows
“Select Menu”. Follow the same steps as to enroll the second administrator’s fingerprint
and code to complete the enrollment.
4. Set time delay (Level 2)
Place an enrolled administrator’s finger (ID No. 01 or 02) on the reader window and hold.
After the fingerprint and its bound code are verified successfully, then the LCD screen
shows “Select Menu”, press “Menu/OK”. Press “
” or “
” to select “Set/Cancel Time Delay”.
12/11:34
8.6V
Set/Cancel
Time Delay
Press “Menu/OK”.
12/11:34
8.6V
Time Delay
00 min
Press “
” or “
” to set time delay (1 to 99 min). Press “Menu/OK”
12/11:34
8.6V
Time Window
01 min
Press “
” or “
” to set Time Window (0 to 15 min). Press “Menu/OK”.
ATTENTION:
During Time Delay period, user can operate the entry pad, such as enrolling deleting etc.,
but the actuator will not be unlocked.
After the original time delay is changed successfully, the time delay for the first time
unlocking is the same as the original one. The new time delay will be effective afterwards.
When changing time delay, if the period is longer than the previous one, the new time
delay will be effective in the next unlocking. If the period is shorter than the previous one,
the new time delay will be effective after the next unlocking.
5. Unlock by an enrolled fingerprint and its bound code (Level 2)
Place an enrolled fingerprint on the fingerprint reader window and hold until the LCD
shows “ID No. Verified”. Enter its bound code. After the bound code is verified, the entry
pad will be unlocked after Time Delay ends.