background image

 

 

American Security Product Co. 

American Security Product Co. 

 

Operating Instructions for the ESL10 Electronic Safe Lock

 

 

 

Your AMSEC ESL10 Electronic Safe Lock has a Factory Combination of 

 

C-1-2-3-4-5-6-#

 

 

To open the lock, simply press the 

“C” key to clear and wake up the electronics. Now press the 

keys  of  the  combination  one  at  a  time  and  finish  with  the 

“#”  key.  If  the  combination  keyed  is 

correct,  the  lock  will  cycle  open  for  three  (3)  seconds.  During  this  3  second  period,  turn  the 
handle of the safe to the unlocked position and pull the door open. 

 

Here are a few things to remember: 

 

a. 

With each keystroke the red lamp on the keypad will flash and a chirp will be heard. 

 

b. 

If 4 (four) incorrect combinations are entered, the lock will go into a 

“Penalty Lockout” for 15 

minutes to prevent trial and error manipulation attempts at opening the lock. The red lamp 
will flash  once  every 5 seconds during  the penalty period. If you press any key during the 
lockout  period,  the  red  lamp  will  flash  with  a  chirp  8  times  rapidly  to  indicate  the  lockout 
condition. 

 

c. 

Before  keying  the  combination,  be  sure  that  the  handle  of  the  safe  is  in  the  fully  locked 
position to allow the lock to open freely. 

 

d. 

If the lock fails to open or acts strange, replace the batteries with good quality fresh 

alkaline 

9 volt batteries To replace the batteries, simply turn the keypad housing counter-clockwise 
to  the stop  and  pull  it  away  from the  base.  Un-snap  the  old  batteries  and clip  on  the  new 
one. Position them in the pocket at the bottom of the housing and replace it watching that 
the  wires  are  not  pinched.  You  should  replace  your  batteries  once  a  year  to  prevent 
corrosion damage from leakage. 

 

e. 

During the input sequence, if you make a mistake, you can press 

“C” to clear the previous 

input and start over again. 

 

f. 

The ESL10 uses a 

fixed length 6 (six) digit combination

 

g. 

Use only your fingers to key the combination. Sharp objects will result in damage which is 
not covered by the warranty. 

 

h. 

If  at 

any  time 

during  opening  or  combination  changing  the  unit  is  left  without  input  for  10 

(ten) seconds, it returns to a resting condition. If this occurs during a combination change, 
the Old Combination is retained. 

 

i. 

At 

any time 

during opening or combination changing the unit will register the first 5 digits of 

the combination into the 

“buffer” that receives input. The 6

th 

digit will be the last numeric key 

pressed. For example, if your press 

C-1-2-3-4-5

-7-4-5-2-7

-6-# 

the program recognizes only 

the C-1-2-3-4-5-6-# input. The last numeric key pressed continues to replace the one prior 
until the 

“#” key is pressed to indicate completion. This is a security feature that allows you 

to baffle an on-looker that may be trying to memorize your combination. 

 

You may change your combination any time you like and as many times as you like. Once your 
safe is installed, you must change the combination to a number sequence other than the Factory 
Combination of 1-2-3-4-5-6 to insure security. 

 

Note: Combination changes should always be done with the door locked OPEN.

 

 

The  input  of  a  new  combination  is  done  by  keying  a 

“Change  Key”  code,  followed  by the  Old 

Combination  to validate a change and then followed  by  entering the  New Combination twice to 
avoid a keying error. To change the combination, do the following: 

 

a. 

Press the keys 

“C” and then “#”. This is the “Change Key” that activates the change routine. 

The  unit  responds  with  a  short  warbling  tone  (called  the 

“good combo tone”)  and the  red 

lamp strobes with the tone. 

 

b. 

Now key in the Old 6 digit combination, the 

“C” key may be used to clear an error in keying 

at any time. Finish the input with a 

“#” key. 

 

1. 

If  the  combination  keyed  matches  the  existing  combination  in  permanent 
memory, another short good combo tone is sounded. Proceed to 

“c.” 

 

2. 

If the combination keyed is incorrect, the unit responds with 4 short beeps (called 
the  bad  combo  tone)  and  returns  to  rest.  The  combination  change  routine  is 
aborted  and  the  Old  combination  is  retained.  This  also  causes  a  count  up  for 
Penalty Lockout. 

 

c. 

Now key the first pass with the New 6 digit combination followed by a 

“#” key. Again, the “C” 

key may be used to clear an error in keying at any time. 

 

1. 

If  the  combination  input  is  6  digit  in  length,  another  short  good  combo  tone  is 
sounded. Proceed to 

“d.” 

 

2. 

If the combination keyed is not 6 digits long, the unit responds with 4 short beeps 
(called the bad combo tone) and returns to rest. The combination change routine 
is aborted and the Old combination is retained. 

 

d. 

Now key the second verify pass with the New 6 digit combination followed by a 

“#” key. As 

before, the 

“C” key may be used to clear an error in keying at any time. 

 

1. 

If  the  combination  input  matched  the  first  pass,  a  long  good  combo  tone  is 
sounded.  The  New  Combination  replaces  the  Old  Combination  in  permanent 
memory and the unit returns to a resting condition. Proceed to 

“e.” 

 

2. 

If the combination keyed does not match the first pass, the unit responds with the 
bad combo tone  and  returns to  rest.  The combination  change routine is aborted 
and the Old combination is retained. 

 

e. 

Test your New Combination several times prior to closing and locking the safe.

 

 

 

 

Continued on Reverse Side 



Reviews: